Evidence map›Paper›PMID 32767448›Full record

ArticleJournal of clinical laboratory analysis2020

Receptor antibody time-resolved A2 phospholipase bead immunochromatography and its application in idiopathic membranous nephropathy.

Biao Huang, Xue Yang, Wenchen Zhang, Jian Wu, Pengfei Liu, Zhigang Hu, Tingting Wang

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical laboratory analysis, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.8field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Biao HuangCollege of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China.
Xue YangThe Affiliated Wuxi Children's Hospital of Nanjing Medical University, Wuxi People's Hospital affiliated to Nanjing Medical University, Wuxi, China.
Wenchen ZhangThe Affiliated Wuxi Children's Hospital of Nanjing Medical University, Wuxi People's Hospital affiliated to Nanjing Medical University, Wuxi, China.
Jian WuThe First People's Hospital of Yancheng City, Yancheng, China.
Pengfei LiuThe Jiangyin Clinical College of Xuzhou Medical University, Jiangyin, China.
Zhigang HuThe Affiliated Wuxi Children's Hospital of Nanjing Medical University, Wuxi People's Hospital affiliated to Nanjing Medical University, Wuxi, China.ORCID https://orcid.org/0000-0001-5678-2492
Tingting WangThe Affiliated Wuxi Children's Hospital of Nanjing Medical University, Wuxi People's Hospital affiliated to Nanjing Medical University, Wuxi, China.
Second Affiliated Hospital of Nanjing Medical University · CNNantong University · CNXuzhou Medical College · CNZhejiang Sci-Tech University · CN

Funding

Jiangsu provincial key talent program for maternal and child health FRC201741Key Research and Development Program of Zhejiang Province 2020C03066Medical and Public Health Project of Wuxi Sci-Tech Development Fund WX18IIAN027Program for Innovative Research of Wuxi CXTD004Project of Jiangsu Health and Family Planning Commission H2019069Project of Wuxi Health and Family Planning Commission MS201829Social Development Fund of Zhejiang Province LGF20H200008Wuxi Key Medical Talents zdrc006
6 · The paper itself

Abstract

objectiveTo detect phospholipase A2 receptor (PLA2R) antibody by established time-resolved fluorescent bead immunochromatographic assay.

methodsThe reaction time of coupling, pH of the reaction, and coupling ratio of the label to PLA2R were determined. The EDC method was used to covalently couple PLA2R to time-resolved fluorescent beads, which were sprayed onto a bonding pad. PLA2R and rabbit anti-PLA2R antibody sprayed onto a nitrocellulose membrane were used as detection and quality control lines, respectively. Immunochromatographic test strips were prepared to enable rapid detection of PLA2R antibodies. Various technical indicators were evaluated, and the correlation among this method, enzyme-linked immunosorbent assay (ELISA), and serum analysis was examined.

resultsThe pH suitable for labeling was 6.5. The optimal mass ratio of PLA2R protein to fluorescent beads was 0.08:1, and the reaction time of coupling was at least 1.5 hours. The appropriate spray film size of the coupled fluorescent bead was 5 μL/cm, and the appropriate staining concentration of the test line was 0.28 mg/mL. Further, 80 µL of sample was required for the test, and the result was obtained in only 15 minutes. The measurable range of this method was 5-1500 RU/mL. Intra- and inter-assay coefficients of variation were 7.61% and 11.07%, respectively, with an average recovery rate of 93.77%. The method showed a good correlation with ELISA, with a correlation coefficient of 0.936.

conclusionsThis method could better meet the clinical demand for idiopathic membranous nephropathy (IMN) detection.

Indexed as

Glomerulonephritis, MembranousReceptors, Phospholipase A2AnimalsAutoantibodiesChromatography, AffinityHumansRabbitsAutoantibodiesReceptors, Phospholipase A2idiopathic membranous nephropathyimmunochromatographyPLA2R antibodyTime-resolved fluorescent bead

Identifiers

PMID32767448
PMCPMC7755819
OpenAlexW3047629347

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.