Evidence map›Paper›PMID 32766484›Full record

ArticlePediatric quality & safety

Reducing Point-of-care Blood Gas Testing in the Intensive Care Unit through Diagnostic Stewardship: A Value Improvement Project.

Michael J Tchou, Sally May, John Holcomb, Ethan Tanner-Edwards, Kathy Good, Matthew Frazier, Erika L Stalets, Maya Dewan

Open access · diamondAbstract read
In one paragraph

Article in Pediatric quality & safety. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Michael J TchouDepartment of Pediatrics, University of Colorado School of Medicine, Aurora, Colo.
Sally MayDepartment of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio.
John HolcombJames M. Anderson Center for Health Systems Excellence, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio.
Ethan Tanner-EdwardsJames M. Anderson Center for Health Systems Excellence, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio.
Kathy GoodClinical Laboratory Administration, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio.
Matthew FrazierJames M. Anderson Center for Health Systems Excellence, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio.
Erika L StaletsDepartment of Pediatrics, University of Cincinnati, College of Medicine, Cincinnati, Ohio.
Maya DewanJames M. Anderson Center for Health Systems Excellence, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio.
Cincinnati Children's Hospital Medical Center · USUniversity of Cincinnati Medical Center · USUniversity of Colorado Denver · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionOverutilization of point-of-care (POC) testing may reduce the overall value of care due to high-cost cartridges, need for staff training, and quality assurance requirements.

methodsThe Diagnostic Stewardship group at Cincinnati Children's Hospital Medical Center assembled a multidisciplinary team to reduce the use of POC blood gas testing by 20% in the pediatric intensive care unit (PICU). Key drivers of test overutilization included poor knowledge of cost, concern with testing turnaround time, and a lack of a standard definition of when a POC test was appropriate. We calculated weekly the outcome measure of POC blood gas tests per PICU patient-day and a balancing measure of blood gas result turnaround time using data extracted from the electronic medical record. Interventions focused on staff education, the establishment of a standard practice guideline for the use of POC testing, and improving turnaround time for laboratory blood gas testing.

resultsOver the baseline period starting July 2016, a median of 0.94 POC blood gas tests per PICU patient-day was ordered. After initial staff training, the rate was reduced to 0.60 tests per PICU patient-day and further reduced to 0.41 tests per PICU patient-day after a formal policy change was adopted. We have sustained this rate for 15 months through June 2018. Institutional direct cost savings were estimated to be $19,000 per year.

conclusionsOur improvement initiative was associated with a significant and rapid reduction in the use of POC testing in the PICU. Interventions focused on cost awareness, and a formal guideline helped establish a consensus around appropriate utilization.