Evidence map›Paper›PMID 32761692›Full record

ArticleNMR in biomedicine2020

Rapid single scan ramped hybrid-encoding for bicomponent T2* mapping in a human knee joint: A feasibility study.

Hyungseok Jang, Alan B McMillan, Yajun Ma, Saeed Jerban, Eric Y Chang, Jiang Du, Richard Kijowski

Abstract read
In one paragraph

Article in NMR in biomedicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Hyungseok JangDepartment of Radiology, University of California San Diego, San Diego, California, USA.ORCID 0000-0002-3597-9525
Alan B McMillanDepartment of Radiology, University of Wisconsin Madison, Madison, Wisconsin, USA.
Yajun MaDepartment of Radiology, University of California San Diego, San Diego, California, USA.ORCID 0000-0003-0830-9232
Saeed JerbanDepartment of Radiology, University of California San Diego, San Diego, California, USA.ORCID 0000-0001-6450-2892
Eric Y ChangDepartment of Radiology, University of California San Diego, San Diego, California, USA.
Jiang DuDepartment of Radiology, University of California San Diego, San Diego, California, USA.ORCID 0000-0002-9203-2450
Richard KijowskiDepartment of Radiology, University of Wisconsin Madison, Madison, Wisconsin, USA.

Funding

Ultrashort Echo Time (UTE) Magnetic Resonance Imaging of BoneR01AR068987 · NIAMS · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI DU, JIANG · 2015 to 2024
$4.9M
Quantitative UTE MR Imaging: Sensitive Biomarkers for OsteoarthritisR01AR062581 · NIAMS · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI DU, JIANG · 2013 to 2022
$4.1M
Improved Techniques for Substitute CT Generation from MRI datasetsR01EB026708 · NIBIB · UNIVERSITY OF WISCONSIN-MADISON · PI MCMILLAN, ALAN BLAIR · 2018 to 2021
$1.8M
Multi-component T2 and T2* mapping of All Water Components of Articular CartilageR01AR068373 · NIAMS · UNIVERSITY OF WISCONSIN-MADISON · PI KIJOWSKI, RICHARD · 2015 to 2018
$1.4M
Quantitative Magnetic Resonance Imaging of Human Rotator Cuff TendonI01CX001388 · VA · VA SAN DIEGO HEALTHCARE SYSTEM · PI CHANG, ERIC Y · 2016 to 2024
–
Quantitative Measurement of Joint pH with Magnetic Resonance ImagingI01RX002604 · VA · VA SAN DIEGO HEALTHCARE SYSTEM · PI CHANG, ERIC Y · 2018 to 2022
–
CSRD VA I01 CX001388NIAMS NIH HHS R01 AR062581NIAMS NIH HHS R01 AR068373NIAMS NIH HHS R01 AR068987NIBIB NIH HHS R01 EB026708RRD VA I01 RX002604
6 · The paper itself

Abstract

The purpose of this study is to determine the feasibility of using a single scan ramped hybrid-encoding (RHE) method for rapid bicomponent T2* analysis of the human knee joint. The proposed method utilizes RHE to acquire ultrashort echo time (UTE) and subsequent gradient echo images at 16 different echo times ranging between 40 μs and 30 ms in a single scan. In the proposed RHE technique, UTE imaging was followed by acquisition of 14 gradient recalled echo images, where an additional UTE image was obtained within the first readout by oversampling single point imaging (SPI) encoding. The single scan RHE method with a 9-minute scan time was performed on human cadaveric knee joints from six donors and in vivo knee joints from four healthy volunteers at 3 T. A bicomponent signal model was used to characterize the short T2* and long T2* water components. Mean bicomponent T2* parameters for patellar tendon, anterior cruciate ligament (ACL), posterior cruciate ligament (PCL) and meniscus were calculated. In the experimental results, the RHE technique provided bicomponent T2* parameter estimations of tendon, ACL, PCL and meniscus, which were similar to previously reported values in the literature. In conclusion, the proposed single scan RHE technique provides rapid bicomponent T2* analysis of the human knee joint with a total scan time of less than 9 minutes.

Indexed as

Magnetic Resonance ImagingFeasibility StudiesHumansImage Processing, Computer-AssistedKnee JointLigamentsMaleMenisci, TibialMiddle AgedTendonsbicomponenthybrid-encodingkneePETRARHESPIT2*UTE

Identifiers

PMID32761692
PMCPMC7584401

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.