ArticleBMC musculoskeletal disorders2020
Mechanical wear analysis helps understand a mechanism of failure in retrieved magnetically controlled growing rods: a retrieval study.
Article in BMC musculoskeletal disorders, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it, 13 citations in OpenAlex.
- Internal mechanism failure of magnetic controlled growing rods (MCGRs) for early-onset scoliosis: a systematic review of implant retrieval analysis studies.Spine deformity · 2026Pooled it
- Advancing Scoliosis Treatment with Patient-Specific Functionally Graded NiTi-SMA Rods: Key Considerations and Development Objectives.Bioengineering (Basel, Switzerland) · 2026Review
- The Performance of MAGEC X Spine Rods: A Comparative Retrieval Study.Global spine journal · 2024Article
- Growing rods in Early Onset Scoliosis: The current scenario.Journal of orthopaedics · 2023Article
- The magnetic field strength and the force distance dependency of the magnetically controlled growing rods used for early onset scoliosis.Scientific reports · 2023Article
- Titanium wear from magnetically controlled growing rods (MCGRs) for the treatment of spinal deformities in children.Scientific reports · 2022Article
- Current benchtop protocols are not appropriate for the evaluation of distraction-based growing rods: a literature review to justify a new protocol and its development.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2022Review
- Inter- and intrarater reliability of measuring lengthening of magnetically controlled growing rods on digital radiographs.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2021Article
- The STRYDE limb lengthening nail is susceptible to mechanically assisted crevice corrosion: an analysis of 23 retrieved implants.Acta orthopaedica · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTo assess the relationship between mechanical wear and the failure of the internal lengthening mechanism in retrieved MAGnetic Expansion Control (MAGEC) growing rods.
methodsThis study included 34 MAGEC rods retrieved from 20 patients. The state of the internal mechanism and mechanical wear were assessed in all the rods using plain radiographs and visual inspection. Metrology was then performed to assess the topography and mechanical wear of the telescopic bars, using a Talyrond 365 (Taylor Hobson, Leicester, UK) roundness measuring machine.
resultsPlain radiographs showed evidence of a broken internal mechanism in 29% of retrieved rods. Single-side wear marks were found in 97% of retrieved rods. Material loss was found to significantly increase in rods with a damaged internal mechanism (p < 0.05) and rods with longer time in situ (r = 0.692, p < 0.05).
conclusionsWe found an association between damage to the internal mechanism of the rods and (1) patterns of single-side longitudinal wear marks and (2) increased material loss. As the material loss was also found to increase over time of rod in situ, we emphasise the importance of early detection and revision of failed MAGEC rods in clinical practice.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials