ArticleOptics express2020
A MEMS lens scanner based on serpentine electrothermal bimorph actuators for large axial tuning.
Article in Optics express, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 21 citations in OpenAlex.
- A Large-Scan-Range Electrothermal Micromirror Integrated with Thermal Convection-Based Position Sensors.Micromachines · 2024Article
- MEMS Enabled Miniature Two-Photon Microscopy for Biomedical Imaging.Micromachines · 2023Review
- Theoretical and Experimental Study on Hot-Embossing of Glass-Microprism Array without Online Cooling Process.Micromachines · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 2 countries.
Funding
Abstract
Confocal microscopes and two-photon microscopes are powerful tools for early cancer diagnosis because of their high-resolution 3D imaging capability, but applying them for clinical use in internal organs is hindered by the lack of axially tunable lens modules with small size, high image quality and large tuning range. This paper reports a compact MEMS lens scanner that has the potential to overcome this limitation. The MEMS lens scanner consists of a MEMS microstage and a microlens. The MEMS microstage is based on a unique serpentine inverted-series-connected (ISC) electrothermal bimorph actuator design. The microlens is an aspheric glass lens to ensure optical quality. The MEMS microstage has been fabricated and the lens scanner has been successfully assembled. The entire lens scanner is circular with an outer diameter of 4.4 mm and a clear optical aperture of 1.8 mm. Experiments show that the tunable range reaches over 200 µm at only 10.5 V and the stiffness of the microstage is 6.2 N/m. Depth scan imaging by the MEMS lens scanner has also been demonstrated with a 2.2 µm resolution, only limited by the available resolution target.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.