Evidence map›Paper›PMID 32752329›Full record

ArticleOptics express2020

Automated fast computational adaptive optics for optical coherence tomography based on a stochastic parallel gradient descent algorithm.

Dan Zhu, Ruoyan Wang, Mantas Žurauskas, Paritosh Pande, Jinci Bi, Qun Yuan, Lingjie Wang, Zhishan Gao, Stephen A Boppart

Open access · goldAbstract read
In one paragraph

Article in Optics express, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.1field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 19 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Dan Zhu
Ruoyan Wang
Mantas Žurauskas
Paritosh Pande
Jinci Bi
Qun Yuan
Lingjie Wang
Zhishan Gao
Stephen A Boppart

Funding

Integration of Raman Spectroscopy and Optical Coherence Tomography (RS-OCT) for In-Vivo Identification of Bacterial Otitis MediaR01EB028615 · NIBIB · UNIVERSITY OF ILLINOIS AT URBANA-CHAMPAIGN · PI BOPPART, STEPHEN A, MAHADEVAN-JANSEN, ANITA · 2019 to 2022
$2.5M
Intraoperative Polarization-Sensitive OCT for Assessing Breast Tumor MarginsR01CA213149 · NCI · UNIVERSITY OF ILLINOIS AT URBANA-CHAMPAIGN · PI BOPPART, STEPHEN A · 2017 to 2021
$2.4M
NCI NIH HHS R01 CA213149NIBIB NIH HHS R01 EB028615
6 · The paper itself

Abstract

The transverse resolution of optical coherence tomography is decreased by aberrations introduced from optical components and the tested samples. In this paper, an automated fast computational aberration correction method based on a stochastic parallel gradient descent (SPGD) algorithm is proposed for aberration-corrected imaging without adopting extra adaptive optics hardware components. A virtual phase filter constructed through combination of Zernike polynomials is adopted to eliminate the wavefront aberration, and their coefficients are stochastically estimated in parallel through the optimization of the image metrics. The feasibility of the proposed method is validated by a simulated resolution target image, in which the introduced aberration wavefront is estimated accurately and with fast convergence. The computation time for the aberration correction of a 512 × 512 pixel image from 7 terms to 12 terms requires little change, from 2.13 s to 2.35 s. The proposed method is then applied for samples with different scattering properties including a particle-based phantom, ex-vivo rabbit adipose tissue, and in-vivo human retina photoreceptors, respectively. Results indicate that diffraction-limited optical performance is recovered, and the maximum intensity increased nearly 3-fold for out-of-focus plane in particle-based tissue phantom. The SPGD algorithm shows great potential for aberration correction and improved run-time performance compared to our previous Resilient backpropagation (Rprop) algorithm when correcting for complex wavefront distortions. The fast computational aberration correction suggests that after further optimization our method can be integrated for future applications in real-time clinical imaging.

Identifiers

PMID32752329
PMCPMC7470677
OpenAlexW3041141234

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.