ArticleSensors (Basel, Switzerland)2020
Higher-Order Models for Resonant Viscosity and Mass-Density Sensors.
Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
Abstract
Advanced fluid models relating viscosity and density to resonance frequency and quality factor of vibrating structures immersed in fluids are presented. The numerous established models which are ultimately all based on the same approximation are refined, such that the measurement range for viscosity can be extended. Based on the simple case of a vibrating cylinder and dimensional analysis, general models for arbitrary order of approximation are derived. Furthermore, methods for model parameter calibration and the inversion of the models to determine viscosity and/or density from measured resonance parameters are shown. One of the two presented fluid models is a viscosity-only model, where the parameters of it can be calibrated without knowledge of the fluid density. The models are demonstrated for a tuning fork-based commercial instrument, where maximum deviations between measured and reference viscosities of approximately ±0.5% in the viscosity range from 1.3 to 243 mPas could be achieved. It is demonstrated that these results show a clear improvement over the existing models.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.