Evidence map›Paper›PMID 32751236›Full record

ArticleBiosensors2020

Development of a Ratiometric Fluorescent Glucose Sensor Using an Oxygen-Sensing Membrane Immobilized with Glucose Oxidase for the Detection of Glucose in Tears.

Hong Dinh Duong, Ok-Jae Sohn, Jong Il Rhee

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
2.1field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 33 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Wearable biosensors for human fatigue diagnosis: A review.Bioengineering & translational medicine · 2023
    Review
  5. Article
  6. Review
  7. Review
  8. Article
  9. Advances in Biosensors for Continuous Glucose Monitoring Towards Wearables.Frontiers in bioengineering and biotechnology · 2021
    Review
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Hong Dinh DuongSchool of Chemical Engineering and Research Center for Biophotonics, Chonnam National University, Gwangju 61186, Korea.
Ok-Jae SohnJoinTree Co., GwangJu 62421, Korea.
Jong Il RheeSchool of Chemical Engineering and Research Center for Biophotonics, Chonnam National University, Gwangju 61186, Korea.ORCID 0000-0003-3890-5246
Chonnam National University · KR

Funding

Industrial Strategic Technology Development Program Sensor Industry Advancement Technology Development Project 20004005National Research Foundation of Korea NRF-2019R1I1A3A01057222
6 · The paper itself

Abstract

Glucose concentration is an important parameter in biomedicine since glucose is involved in many metabolic pathways in organisms. Many methods for glucose detection have been developed for use in various applications, particularly in the field of healthcare in diabetics. In this study, ratiometric fluorescent glucose-sensing membranes were fabricated based on the oxygen levels consumed in the glucose oxidation reaction under the catalysis of glucose oxidase (GOD). The oxygen concentration was measured through the fluorescence quenching effect of an oxygen-sensitive fluorescent dye like platinum meso-tetra (pentafluorophenyl) porphyrin (PtP) by oxygen molecules. Coumarin 6 (C6) was used as a reference dye in the ratiometric fluorescence measurements. The glucose-sensing membrane consisted of two layers: The first layer was the oxygen-sensing membrane containing polystyrene particles (PS) doped with PtP and C6 (e.g., PS@C6^PtP) in a sol-gel matrix of aminopropyltrimethoxysilane and glycidoxypropyltrimethoxysilane (GA). The second layer was made by immobilizing GOD onto one of three supporting polymers over the first layer. These glucose-sensing membranes were characterized in terms of their response, reversibility, interferences, and stability. They showed a wide detection range to glucose concentration in the range of 0.1 to 10 mM, but high sensitivity with a linear detection range of 0.1 to 2 mM glucose. This stable and sensitive ratiometric fluorescent glucose biosensor provides a reliable way to determine low glucose concentrations in blood serum by measuring tear glucose.

Indexed as

Biosensing TechniquesCoumarinsFluorescent DyesGlucoseGlucose OxidaseTearsThiazolescoumarin 6CoumarinsFluorescent DyesGlucoseGlucose OxidaseThiazolesfluorescence quenchingglucose oxidaseglucose-sensing membraneratiometric fluorescent sensortear glucose

Identifiers

PMID32751236
PMCPMC7459645
OpenAlexW3046199946

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.