ArticleSurgical endoscopy2021

Assessment of a novel stapler performance for laparoscopic sleeve gastrectomy.

Christen Salyer, Anthony Spuzzillo, Devin Wakefield, Dina Gomaa, Jonathan Thompson, Michael Goodman

Abstract read
PubMed Publisher
In one paragraph

Article in Surgical endoscopy, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.5field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Implementation of a Safe Cost Reduction Strategy for Laparoscopic Sleeve Gastrectomy.JSLS : Journal of the Society of Laparoendoscopic Surgeons
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Christen SalyerDivision of Research, Section of General Surgery, Department of Surgery, University of Cincinnati, Cincinnati, OH, USA.ORCID http://orcid.org/0000-0002-8134-9217
Anthony SpuzzilloSection of General Surgery, University of Cincinnati Medical Center, Cincinnati, OH, USA.
Devin WakefieldSection of General Surgery, University of Cincinnati Medical Center, Cincinnati, OH, USA.
Dina GomaaSection of General Surgery, University of Cincinnati Medical Center, Cincinnati, OH, USA.
Jonathan ThompsonSection of General Surgery, University of Cincinnati Medical Center, Cincinnati, OH, USA.
Michael GoodmanSection of General Surgery, University of Cincinnati Medical Center, Cincinnati, OH, USA. michael.goodman@uc.edu.
University of Cincinnati · USAmerican Standard (United States) · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundOptimal stapler selection during laparoscopic sleeve gastrectomy requires careful balance between tissue compression, hemostasis, and mechanical integrity. Junctions along a staple line can further increase the risks of technical or mechanical staple line failures. The aim of this study was to compare two commonly utilized laparoscopic linear gastrointestinal staplers (Ethicon, Medtronic) with a novel linear stapler (Titan) designed to perform a sleeve gastrectomy with a single stapler firing.

methodsExcised gastric remnants from laparoscopic sleeve gastrectomy were utilized and tissue thickness was measured from fundus to antrum. An optimized experimental staple line was then created. The greater curve remnant was insufflated to determine the staple line burst pressure and location. The doubly stapled (clinical and experimental) gastric specimen underwent staple analysis for junctional location, malformation, and height.

resultsThe Titan stapler withstood a significantly higher burst pressure than both Ethicon and Medtronic linear cutting staplers. While the Medtronic and Ethicon staplers had a similar percentage of staples in junctions, the Titan stapler has no junctions. In considering the formation of all staples outside of junctions, the Medtronic and Titan staplers had no difference in percentage of malformed staples, while the Ethicon stapler had a significantly higher percentage. Additionally, there were no differences in mismatch between staple height and tissue thickness between experimental groups.

conclusionsThe Titan stapler conveys the mechanical benefits of higher burst pressure with the advantage of single load functionality. This single staple load eliminates staple line junctions without sacrificing the integrity of staple formation.

Indexed as

Gastric StumpLaparoscopyGastrectomyHumansSurgical StaplersSurgical StaplingBariatricsNovel staplerSleeve gastrectomySurgical staples

Identifiers

PMID32749610
OpenAlexW3047038026

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials