Evidence map›Paper›PMID 32746131›Full record

ArticleIEEE transactions on medical imaging2020

Low Dose CT Perfusion With K-Space Weighted Image Average (KWIA).

Chenyang Zhao, Thomas Martin, Xingfeng Shao, Jeffry R Alger, Vinay Duddalwar, Danny J J Wang

Abstract read
In one paragraph

Article in IEEE transactions on medical imaging, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. New imaging techniques and trends in radiology.Diagnostic and interventional radiology (Ankara, Turkey) · 2025
    Review
  2. Article
  3. Article
  4. Article
  5. [Nonlocal low-rank and sparse matrix decomposition for low-dose cerebral perfusion CT image restoration].Nan fang yi ke da xue xue bao = Journal of Southern Medical University · 2022
    Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Chenyang Zhao
Thomas Martin
Xingfeng Shao
Jeffry R Alger
Vinay Duddalwar
Danny J J Wang

Funding

Multiband ASL for Neurodevelopment StudyR01EB028297 · NIBIB · UNIVERSITY OF SOUTHERN CALIFORNIA · PI WANG, DANNY JJ · 2019 to 2023
$2.2M
Novel Algorithms for Reducing Radiation Dose of CT PerfusionR44EB024438 · NIBIB · HURA IMAGING, INC · PI ALGER, JEFFRY R, WANG, DANNY JJ · 2020 to 2021
$1.6M
A Novel System for Reducing Radiation Dose of CT PerfusionR41EB024438 · NIBIB · HURA IMAGING, INC · PI WANG, DANNY JJ · 2017 to 2017
$266k
NIBIB NIH HHS R01 EB028297NIBIB NIH HHS R41 EB024438NIBIB NIH HHS R44 EB024438
6 · The paper itself

Abstract

CTP (Computed Tomography Perfusion) is widely used in clinical practice for the evaluation of cerebrovascular disorders. However, CTP involves high radiation dose (≥~200mGy) as the X-ray source remains continuously on during the passage of contrast media. The purpose of this study is to present a low dose CTP technique termed K-space Weighted Image Average (KWIA) using a novel projection view-shared averaging algorithm with reduced tube current. KWIA takes advantage of k-space signal property that the image contrast is primarily determined by the k-space center with low spatial frequencies and oversampled projections. KWIA divides each 2D Fourier transform (FT) or k-space CTP data into multiple rings. The outer rings are averaged with neighboring time frames to achieve adequate signal-to-noise ratio (SNR), while the center region of k-space remains unchanged to preserve high temporal resolution. Reduced dose sinogram data were simulated by adding Poisson distributed noise with zero mean on digital phantom and clinical CTP scans. A physical CTP phantom study was also performed with different X-ray tube currents. The sinogram data with simulated and real low doses were then reconstructed with KWIA, and compared with those reconstructed by standard filtered back projection (FBP) and simultaneous algebraic reconstruction with regularization of total variation (SART-TV). Evaluation of image quality and perfusion metrics using parameters including SNR, CNR (contrast-to-noise ratio), AUC (area-under-the-curve), and CBF (cerebral blood flow) demonstrated that KWIA is able to preserve the image quality, spatial and temporal resolution, as well as the accuracy of perfusion quantification of CTP scans with considerable (50-75%) dose-savings.

Indexed as

AlgorithmsTomography, X-Ray ComputedPerfusionPhantoms, ImagingRadiation DosageRadiographic Image Interpretation, Computer-AssistedSignal-To-Noise Ratio

Identifiers

PMID32746131
PMCPMC7704693

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.