ArticleIEEE transactions on medical imaging2020
Throughput-Speed Product Augmentation for Scanning Fiber-Optic Two-Photon Endomicroscopy.
Article in IEEE transactions on medical imaging, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 32 citations in OpenAlex.
- High-speed neural imaging with multiplexed miniaturized two-photon microscopy.Cell reports methods · 2025Article
- Alleviating head-mounted weight burden for neural imaging in freely-behaving rodents.Scientific reports · 2025Article
- Two-photon fiberscope with a proactive optoelectrical commutator for rotational resistance-free imaging in freely behaving rodents.Neurophotonics · 2025Article
- Cervical Collagen Network Porosity Assessed by SHG Endomicroscopy Distinguishes Preterm and Normal Pregnancy-A Pilot Study.IEEE transactions on bio-medical engineering · 2025Article
- Video-rate two-photon microendoscopy using second harmonic resonance fiber scanning.Biomedical optics express · 2024Article
- SHG Fiberscopy Assessment of Collagen Morphology and Its Potential for Breast Cancer Optical Histology.IEEE transactions on bio-medical engineering · 2024Article
- Fiber optic-based integrated system forBiomedical optics express · 2024Article
- Field curvature reduction in miniaturized high numerical aperture and large field-of-view objective lenses with sub 1 µm lateral resolution.Biomedical optics express · 2023Article
- Two-Photon Endoscopy: State of the Art and Perspectives.Molecular imaging and biology · 2023Review
- Label-Free Metabolic Imaging In Vivo by Two-Photon Fluorescence Lifetime Endomicroscopy.ACS photonics · 2022Article
- Learned end-to-end high-resolution lensless fiber imaging towards real-time cancer diagnosis.Scientific reports · 2022Article
- Twist-free ultralight two-photon fiberscope enabling neuroimaging on freely rotating/walking mice.Optica · 2021Article
- Multicolor fiber-optic two-photon endomicroscopy for brain imaging.Optics letters · 2021Article
- Scanning and Actuation Techniques for Cantilever-Based Fiber Optic Endoscopic Scanners-A Review.Sensors (Basel, Switzerland) · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 3 institutions in 1 country.
Funding
Abstract
Compactness, among several others, is one unique and very attractive feature of a scanning fiber-optic two-photon endomicroscope. To increase the scanning area and the total number of resolvable pixels (i.e., the imaging throughput), it typically requires a longer cantilever which, however, leads to a much undesired, reduced scanning speed (and thus imaging frame rate). Herein we introduce a new design strategy for a fiber-optic scanning endomicroscope, where the overall numerical aperture (NA) or beam focusing power is distributed over two stages: 1) a mode-field focuser engineered at the tip of a double-clad fiber (DCF) cantilever to pre-amplify the single-mode core NA, and 2) a micro objective of a lower magnification (i.e., ∼ 2× in this design) to achieve final tight beam focusing. This new design enables either an ~9-fold increase in imaging area (throughput) or an ~3-fold improvement in imaging frame rate when compared to traditional fiber-optic endomicroscope designs. The performance of an as-designed endomicroscope of an enhanced throughput-speed product was demonstrated by two representative applications: (1) high-resolution imaging of an internal organ (i.e., mouse kidney) in vivo over a large field of view without using any fluorescent contrast agents, and (2) real-time neural imaging by visualizing dendritic calcium dynamics in vivo with sub-second temporal resolution in GCaMP6m-expressing mouse brain. This cascaded NA amplification strategy is universal and can be readily adapted to other types of fiber-optic scanners in compact linear or nonlinear endomicroscopes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.