ArticleCanadian Urological Association journal = Journal de l'Association des urologues du Canada2021
Comparison of a magnetic retrieval device vs. flexible cystoscopy for removal of ureteral stents in renal transplant patients: A randomized controlled trial.
Article in Canadian Urological Association journal = Journal de l'Association des urologues du Canada, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it, 8 citations in OpenAlex.
- Pooled it
- The Function Improved of the Newly Designed Magnetic-End Ureteric Stenting Retrieval Device: A Clinical Prospective Randomized and Control Trial in a Multicenter Study.Contrast media & molecular imaging · 2022Trial
- An evidence-based review by the EAU Endourology on standard practices and future directions for ureteral stents in transplant patients.World journal of urology · 2026Review
- From biofilms to fibrosis: recent advances in research on the pathological microenvironment linked to ureteral stents and their surface functionalization.Frontiers in bioengineering and biotechnology · 2026Review
- Comparison of Magnetic and Conventional Double-J Stent Following Kidney Transplantation: A Randomized Controlled Trial.Transplantation direct · 2025Article
- The "ins and outs" of the magnetic ureteral stent: A novel innovation in Endourology.Current urology · 2023Article
- Comparison of the Removal Efficiency and Safety of Magnetic Versus Conventional Ureteral Stents: A Systematic Review and Meta-analysis.European urology open science · 2023Review
- Feasibility and Safety of a Simple Non-cystoscopic Double-J Tube Removal Technique in Children.Frontiers in pediatrics · 2021Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionPlacement of a ureteral stent at the time of renal transplantation can reduce complications when compared to non-stented anastomoses. Removal by flexible cystoscopy can be associated with discomfort, risk for infection, and high costs. New magnetic stents offer a means of bypassing cystoscopy by use of a magnetic retrieval device. Our objective was to compare clinical and cost-related outcomes of conventional and magnetic stents in patients undergoing deceased donor renal transplantation.
methodsPatients were randomized to receive either a conventional or a Black-Star
resultsForty-one patients were randomized to conventional (n=19) or Black-Star (n=22) stent. The total time for stent removal under cystoscopy was significantly longer compared to Black-Star removal (6.67±2.47 and 4.80±2.21 minutes, respectively, p=0.019). No differences were found in the USSQ domains between groups. Rates of urinary tract infections and surgical complications between groups were similar. Stent removal was well-tolerated in both groups. Black-Star stent use resulted in a cost savings of $304.02 Canadian dollars (CAD) per case.
conclusionsUSSQ scores suggest that stent removal with the Black-Star magnetic stent is as equally well-tolerated as flexible cystoscopy by renal transplant patients. Black-Star stent removal was significantly faster than conventional stents. No differences in discomfort, infection rate, or complication rate were found. Use of the Black-Star stent resulted in an estimated annual savings of $27 360 CAD at our centre.
Identifiers
What OpenQuestion holds
Registered trials