Evidence map›Paper›PMID 32740342›Full record

ReviewASAIO journal (American Society for Artificial Internal Organs : 1992)2020

Toward a Long-Term Artificial Lung.

Jutta Arens, Oliver Grottke, Axel Haverich, Lars S Maier, Thomas Schmitz-Rode, Ulrich Steinseifer, H P Wendel, Rolf Rossaint

Open access · hybridAbstract readReview
In one paragraph

Review in ASAIO journal (American Society for Artificial Internal Organs : 1992), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
1.8field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 33 citations in OpenAlex.

  1. Article
  2. Article
  3. Future Frontiers in Bioinspired Implanted Biomaterials.Advanced materials (Deerfield Beach, Fla.) · 2025
    Review
  4. Article
  5. Article
  6. A Reduced Resistance, Concentric-Gated Artificial Membrane Lung for Pediatric End-Stage Lung Failure.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2025
    Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Review
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 5 institutions in 2 countries.

Jutta ArensFrom the Chair in Engineering Organ Support Technologies, Department of Biomechanical Engineering, Faculty of Engineering Technologies, University of Twente, Enschede, The Netherlands.ORCID 0000-0002-9115-0519
Oliver GrottkeDepartment of Anesthesiology, Medical Faculty, RWTH Aachen University, Aachen, Germany.
Axel HaverichThoracic, Cardiac and Vascular Surgery, Medizinische Hochschule Hannover, Hannover, Germany.
Lars S MaierInternal Medicine II, Universitätsklinikum Regensburg, Regensburg, Germany.
Thomas Schmitz-RodeInstitute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany.ORCID 0000-0002-1181-2165
Ulrich SteinseiferDepartment of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty.
H P WendelThoracic, Cardiac and Vascular Surgery, Universitätsklinikum Tübingen, Tübingen, Germany.
Rolf RossaintDepartment of Anesthesiology, Medical Faculty, RWTH Aachen University, Aachen, Germany.
RWTH Aachen University · DEMedizinische Hochschule Hannover · DEUniversitätsklinikum Tübingen · DEUniversity Hospital Regensburg · DEUniversity of Twente · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Only a very small portion of end-stage organ failures can be treated by transplantation because of the shortage of donor organs. Although artificial long-term organ support such as ventricular assist devices provide therapeutic options serving as a bridge-to-transplantation or destination therapy for end-stage heart failure, suitable long-term artificial lung systems are still at an early stage of development. Although a short-term use of an extracorporeal lung support is feasible today, the currently available technical solutions do not permit the long-term use of lung replacement systems in terms of an implantable artificial lung. This is currently limited by a variety of factors: biocompatibility problems lead to clot formation within the system, especially in areas with unphysiological flow conditions. In addition, proteins, cells, and fibrin are deposited on the membranes, decreasing gas exchange performance and thus, limiting long-term use. Coordinated basic and translational scientific research to solve these problems is therefore necessary to enable the long-term use and implantation of an artificial lung. Strategies for improving the biocompatibility of foreign surfaces, for new anticoagulation regimes, for optimization of gas and blood flow, and for miniaturization of these systems must be found. These strategies must be validated by in vitro and in vivo tests, which remain to be developed. In addition, the influence of long-term support on the pathophysiology must be considered. These challenges require well-connected interdisciplinary teams from the natural and material sciences, engineering, and medicine, which take the necessary steps toward the development of an artificial implantable lung.

Indexed as

Artificial OrgansLungAnimalsHumans

Identifiers

PMID32740342
PMCPMC7386861
OpenAlexW3009920252

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.