Evidence map›Paper›PMID 32738073›Full record

ArticleMagnetic resonance in medicine2021

Michael A Ohliger, Jeremy W Gordon, Lucas Carvajal, Peder E Z Larson, Jao J Ou, Shubhangi Agarwal, Zihan Zhu, Daniel B Vigneron, Cornelius von Morze

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. RF coil design for accurate parallel imaging onMagnetic resonance in medicine · 2022
    Article
  3. Specialized computational methods for denoising, BMagnetic resonance in medicine · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Michael A OhligerDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA.ORCID 0000-0001-6878-8189
Jeremy W GordonDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA.ORCID 0000-0003-2760-4886
Lucas CarvajalDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA.
Peder E Z LarsonDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA.ORCID 0000-0003-4183-3634
Jao J OuDepartment of Radiology, Wake Forest School of Medicine, Winston Salem, North Carolina, USA.
Shubhangi AgarwalDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA.
Zihan ZhuDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA.
Daniel B VigneronDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA.
Cornelius von MorzeMallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Missouri, USA.ORCID 0000-0002-3992-1793

Funding

TR&D3: Open-Source Tools for Processing Hyperpolarized MR DataP41EB013598 · NIBIB · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI DUAN XU · 2011 to 2026
$19.9M
Novel hyperpolarized 13C molecular imaging techniques for differentiating NAFLD and NASHR01DK115987 · NIDDK · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI OHLIGER, MICHAEL, VON MORZE, CORNELIUS · 2018 to 2022
$2.1M
NIBIB NIH HHS P41 EB013598NIDDK NIH HHS R01 DK115987
6 · The paper itself

Abstract

purposeTo use fiducial markers containing manganese 55 to rapidly localize carbon 13 (

methodsHollow high-density polyethylene spheres were filled with 3M sodium permanganate and affixed to a rectangular

resultsIn simulations, our algorithm was accurate in determining marker positions when at least 6 projections were used (RMSE 1.4 ± 0.9 mm). These estimates were verified in phantom experiments, where markers locations were determined with an RMS accuracy of 1.3 mm. A minimum SNR of 4 was required for automated detection to perform accurately. Computed coil sensitivity had a median error of 17% when taken over the entire measured area and 5.7% over a central region. In a rat, correction for nonuniform reception and flip angle was able to normalize the signals arising from asymmetrically positioned kidneys.

conclusionManganese 55 fiducial markers are an inexpensive and reliable method for rapidly localizing

Indexed as

Fiducial MarkersMagnetic Resonance ImagingAlgorithmsAnimalsPhantoms, ImagingRadio WavesRatscoil sensitivityfiducialshyperpolarized carbonmanganeseRF coil

Identifiers

PMID32738073
PMCPMC8354199

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked