ArticleFrontiers in physiology2020
Influences of Sensor Placement Site and Subject Posture on Measurement of Respiratory Frequency Using Triaxial Accelerometers.
Article in Frontiers in physiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 18 citations in OpenAlex.
- A Stand-Alone Wearable Measurement System for Continuous Hand Tremor Monitoring.Sensors (Basel, Switzerland) · 2026Article
- Determination of cut-off points for the Move4 accelerometer and assessment of energy expenditure in children and adolescents aged 6-16 years using manual wheelchairs: a validation and calibration study.Journal of neuroengineering and rehabilitation · 2026Article
- NAPping PAnts (NAPPA): An open wearable solution for monitoring Infant's sleeping rhythms, respiration and posture.Heliyon · 2024Article
- An Inertial-Based Wearable System for Monitoring Vital Signs during Sleep.Sensors (Basel, Switzerland) · 2024Article
- Flexible Textile Sensors-Based Smart T-Shirt for Respiratory Monitoring: Design, Development, and Preliminary Validation.Sensors (Basel, Switzerland) · 2024Article
- Real-Time Evaluation of Time-Domain Pulse Rate Variability Parameters in Different Postures and Breathing Patterns Using Wireless Photoplethysmography Sensor: Towards Remote Healthcare in Low-Resource Communities.Sensors (Basel, Switzerland) · 2023Article
- A Differential Inertial Wearable Device for Breathing Parameter Detection: Hardware and Firmware Development, Experimental Characterization.Sensors (Basel, Switzerland) · 2022Article
- Wearable Sensors for Remote Health Monitoring: Potential Applications for Early Diagnosis of Covid-19.Advanced materials technologies · 2022Review
- Assessing the Transferability of Physical Activity Type Detection Models: Influence of Age Group Is Underappreciated.Frontiers in physiology · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionRespiration frequency (RF) could be derived from the respiratory signals recorded by accelerometers which detect chest wall movements. The optimum direction of acceleration for accurate RF measurement is still uncertain. We aim to investigate the effect of measure site, posture, and direction of acceleration on the accuracy of accelerometer-based RF estimation.
methodsIn supine and seated postures respectively, respiratory signals were measured from 34 healthy subjects in 70 s by triaxial accelerometers located at four sites on the body wall (over the clavicle, laterally on the chest wall, over the pectoral part of the anterior chest wall, on the abdomen in the midline at the umbilicus), with the reference respiratory signal simultaneously recorded by a strain gauge chest belt. RFs were extracted from the accelerometer and reference respiratory signals using wavelet transformation. To investigate the effect of measure site, posture, and direction of acceleration on the accuracy of accelerometer-based RF estimation, repeated measures multivariate analysis of variance, linear regression, Bland-Altman analysis, and Scheirer-Ray-Hare test were performed between reference and accelerometer-based RFs.
resultsThere was no significant difference in accelerometer-based RF estimation between seated and supine postures, among four accelerometer sites, or between seated or supine postures (
conclusionRespiration frequency can be accurately measured from the acceleration of any direction using triaxial accelerometers placed at the clavicular, pectoral and lateral sites on the chest as well the mid abdominal site. More accurate RF estimation could be achieved in supine posture compared with seated posture.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials