ArticleClinical orthopaedics and related research2020
The Impingement-free, Prosthesis-specific, and Anatomy-adjusted Combined Target Zone for Component Positioning in THA Depends on Design and Implantation Parameters of both Components.
Article in Clinical orthopaedics and related research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 32 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
32 citing papers in PubMed, 1 synthesis or guideline pooled it, 71 citations in OpenAlex.
- The role of the femoral component orientation on dislocations in THA: a systematic review.Archives of orthopaedic and trauma surgery · 2022Pooled it
- Combined anteversion in natural Asian hips is lower than conventional targets and is predominantly determined by femoral anteversion.International orthopaedics · 2026Article
- Identification of Combined Anteversion Targets to Optimize Impingement-free Range of Motion Across Femoral Head Sizes: A Simulation Study.Arthroplasty today · 2026Article
- Impact of functional evaluation 3D software on impingement and clinical outcomes in robotic-arm assisted total hip arthroplasty.Arthroplasty (London, England) · 2025Article
- [Why does a total hip replacement dislocate? : Diagnosis and management].Orthopadie (Heidelberg, Germany) · 2025Review
- Patient-Specific Acetabular Safe Zones in Total Hip Arthroplasty: External Validation of a Quantitative Approach to Preoperatively Templating Spinopelvic Parameters.Arthroplasty today · 2024Article
- Robotic-assisted total hip arthroplasty outperforms manual technique in obese and overweight patients: a prospective comparative study.Journal of orthopaedic surgery and research · 2024Article
- Polyethylene liner dissociation in total hip arthroplasty: a retrospective case-control study on a single implant design.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2024Article
- Femoral Neck Anteversion: Which Distal Femur Landmark Matters?Arthroplasty today · 2024Article
- How to Estimate Femoral Stem Anteversion During Direct Anterior Approach Total Hip Arthroplasty.Arthroplasty today · 2024Article
- The Long-Term Efficacy of Computed Tomography-Navigated Total Hip Arthroplasty: An 18-Year Follow-Up Study.Journal of clinical medicine · 2024Article
- Insufficient stem antetorsion and lower cup abduction is a combined risk factor for posterior hip dislocation in patients undergoing THA for femoral neck fractures: a retrospective analysis.BMC musculoskeletal disorders · 2024Article
- Variety of femoral anteversion and its measurement in cementless total hip arthroplasty: Does robotic technology improve accuracy?Journal of orthopaedic surgery and research · 2024Article
- Accuracy and safety of a new robotic arm for both femoral and acetabular side in total hip arthroplasty: a cadaveric study.Journal of orthopaedic surgery and research · 2023Article
- A novel method for evaluating combined component anteversion in total hip arthroplasty on cross-table lateral hip radiographs.Archives of orthopaedic and trauma surgery · 2023Article
- How Relevant Is the Parallax Effect on Low Centered Pelvic Radiographs in Total Hip Arthroplasty.Journal of personalized medicine · 2023Article
- Achieving Target Cemented Femoral Stem Anteversion Using a 3-Dimensional Model.Arthroplasty today · 2023Article
- Handheld Navigation Improves Accuracy in Direct Anterior Total Hip Replacement.Arthroplasty today · 2022Article
- Computer simulation of optimal lipped polyethylene liner orientation against prosthetic impingement.Journal of orthopaedic surgery and research · 2022Article
- Distribution and outliers of anteversion of short-length cementless stem.International orthopaedics · 2022Article
Corrections and comments
- Commented on by
Authors and funding
1 author at 1 institution in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundLewinnek's recommendation for orienting the cup in THA is criticized because it involves a static assessment of the safe zone and because it does not consider stem geometry. A revised concept of the safe zone should consider those factors, but to our knowledge, this has not been assessed. QUESTIONS/PURPOSES: (1) To determine the shape, size, and location of target zones for combined cup and stem orientation for a straight stem/hemispheric cup THA to maximize the impingement-free ROM and (2) To determine whether and how these implant positions change as stem anteversion, neck-shaft angle, prosthetic head size and target range of movements are varied.
methodsA three-dimensional computer-assisted design model, in which design geometry was expressed in terms of parameters, of a straight stem/hemispheric cup hip prosthesis was designed, its design parameters modified systematically, and each prosthesis model was implanted virtually at predefined component orientations. Functional component orientation referencing to body planes was used: cups were abducted from 20° to 70°, and anteverted from -10° to 40°. Stems were rotated from -10° to 40° anteversion, neck-shaft angles varied from 115° to 143°, and head sizes varied from 28 to 40 mm. Hip movements up to the point of prosthetic impingement were tested, including simple flexion/extension, internal/external rotation, ab/adduction, combinations of these, and activities of daily living that were known to trigger dislocation. For each combination of parameters, the impingement-free combined target zone was determined. Maximizing the size of the combined target zone was the optimization criterion.
resultsThe combined target zones for impingement-free cup orientation had polygonal boundaries. Their size and position in the diagram changed with stem anteversion, neck-shaft angle, head size, and target ROM. The largest target zones were at neck-shaft angles from 125° to 127°, at stem anteversions from 10° to 20°, and at radiographic cup anteversions between 17° and 25°. Cup anteversion and stem anteversion were inverse-linearly correlated supporting the combined-anteversion concept. The range of impingement-free cup inclinations depended on head size, stem anteversion, and neck-shaft angle. For a 127°-neck-shaft angle, the lowest cup inclinations that fell within the target zone were 42° for the 28-mm and 35° for the 40-mm head. Cup anteversion and combined version depended on neck-shaft angle. For head size 32-mm cup, anteversion was 6° for a 115° neck-shaft angle and 25° for a 135°-neck-shaft angle, and combined version was 15° and 34° respectively.
conclusionsThe shape, size, and location of the combined target zones were dependent on design and implantation parameters of both components. Changing the prosthesis design or changing implantation parameters also changed the combined target zone. A maximized combined target zone was found. It is mandatory to consider both components to determine the accurate impingement-free prosthetic ROM in THA. CLINICAL RELEVANCE: This study accurately defines the hypothetical impingement-free, design-specific component orientation in THA. Transforming it into clinical precision may be the case for navigation and/or robotics, but this is speculative, and as of now, unproven.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.