Evidence map›Paper›PMID 32731474›Full record

ArticleSensors (Basel, Switzerland)2020

Two-Channel Graphene pH Sensor Using Semi-Ionic Fluorinated Graphene Reference Electrode.

Dae Hoon Kim, Woo Hwan Park, Hong Gi Oh, Dong Cheol Jeon, Joon Mook Lim, Kwang Soup Song

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. pH monitoring in high ionic concentration environments: performance study of graphene-based sensors.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2025
    Article
  2. Article
  3. Two-Dimensional Disposable Graphene Sensor to Detect NaNanomaterials (Basel, Switzerland) · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Dae Hoon KimDepartment of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Korea.
Woo Hwan ParkDepartment of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Korea.
Hong Gi OhDepartment of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Korea.
Dong Cheol JeonDepartment of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Korea.
Joon Mook LimDepartment of Creative Convergence Engineering, Hanbat National University, Daejeon 34158, Korea.
Kwang Soup SongDepartment of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A reference electrode is necessary for the working of ion-sensitive field-effect transistor (ISFET)-type sensors in electrolyte solutions. The Ag/AgCl electrode is normally used as a reference electrode. However, the Ag/AgCl reference electrode limits the advantages of the ISFET sensor. In this work, we fabricated a two-channel graphene solution gate field-effect transistor (G-SGFET) to detect pH without an Ag/AgCl reference electrode in the electrolyte solution. One channel is the sensing channel for detecting the pH and the other channel is the reference channel that serves as the reference electrode. The sensing channel was oxygenated, and the reference channel was fluorinated partially. Both the channels were directly exposed to the electrolyte solution without sensing membranes or passivation layers. The transfer characteristics of the two-channel G-SGFET showed ambipolar field-effect transistor (FET) behavior (p-channel and n-channel), which is a typical characteristic curve for the graphene ISFET, and the value of V

Indexed as

fluorinated graphenegraphenepH sensorreference electrode

Identifiers

PMID32731474
PMCPMC7436108

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.