Evidence map›Paper›PMID 32728847›Full record

ArticleEuropean archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery2021

Microsurgical procedures during COVID-19 pandemic: the VITOM® 3D-HD exoscopic system as alternative to the operating microscope to properly use personal protective equipment (PPE).

Andrea Luigi Camillo Carobbio, Marta Filauro, Giampiero Parrinello, Francesco Missale, Giorgio Peretti

Open access · bronzeAbstract read
In one paragraph

Article in European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.2field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. New surgical frontiers for 4K 3D-exoscope in paediatric head and neck surgery.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2023
    Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Andrea Luigi Camillo CarobbioIRCCS Ospedale Policlinico San Martino, Largo Rosanna Benzi, 10, 16132, Genoa, Italy.ORCID https://orcid.org/0000-0002-0919-971X
Marta FilauroIRCCS Ospedale Policlinico San Martino, Largo Rosanna Benzi, 10, 16132, Genoa, Italy.
Giampiero ParrinelloIRCCS Ospedale Policlinico San Martino, Largo Rosanna Benzi, 10, 16132, Genoa, Italy.
Francesco MissaleIRCCS Ospedale Policlinico San Martino, Largo Rosanna Benzi, 10, 16132, Genoa, Italy. missale.francesco@gmail.com.ORCID http://orcid.org/0000-0002-5357-5348
Giorgio PerettiIRCCS Ospedale Policlinico San Martino, Largo Rosanna Benzi, 10, 16132, Genoa, Italy.ORCID https://orcid.org/0000-0003-2362-8936
Ospedale Policlinico San Martino · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeIn the field of microsurgery, the use of conventional operating microscope, adopted in several disciplines, is not suitable with the full adoption of appropriate personal protective equipment (PPE), as goggles and face shields, needing the eyes to be at close contact with oculars.

methodsHerein we present an exoscopic surgical setup, implemented for transoral laser microsurgery, by the VITOM® 3D-HD system.

resultsOur proposed exoscopic setting overcomes safety limits of the conventional operating microscope, being suitable with the adoption of full PPE necessary facing with suspected or confirmed positive SARS-CoV-2 patients needing urgent microsurgical procedures.

conclusionThe use of protocols to reduce the virus spreading is mandatory to safely treat also patients potentially SARS-CoV-2 infected. The described surgical setup is advisable to manage urgent microsurgical procedures along the duration of the COVID-19 pandemic, being applicable PPE necessary to treat potentially or confirmed SARS-CoV-2-infected patients.

Indexed as

COVID-19Personal Protective EquipmentHumansMicrosurgeryPandemicsSARS-CoV-2COVID-19ExoscopeLaryngeal cancerMicroscopePPEVITOM

Identifiers

PMID32728847
PMCPMC7388428
OpenAlexW3045984641

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.