Evidence map›Paper›PMID 32727146›Full record

ArticleSensors (Basel, Switzerland)2020

Fully Automated Segmentation of Bladder Sac and Measurement of Detrusor Wall Thickness from Transabdominal Ultrasound Images.

Zeynettin Akkus, Bae Hyung Kim, Rohit Nayak, Adriana Gregory, Azra Alizad, Mostafa Fatemi

Open access · goldAbstract readLetter
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.4field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 14 citations in OpenAlex.

  1. Review
  2. Article
  3. Application and prospects of AI-based radiomics in ultrasound diagnosis.Visual computing for industry, biomedicine, and art · 2023
    Review
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Zeynettin AkkusDepartment of Cardiology, Mayo Clinic, Rochester, MN 55905, USA.ORCID 0000-0003-3920-1515
Bae Hyung KimDepartment of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, USA.
Rohit NayakDepartment of Radiology, Mayo Clinic, Rochester, MN 55905, USA.ORCID 0000-0002-4353-6951
Adriana GregoryDepartment of Radiology, Mayo Clinic, Rochester, MN 55905, USA.
Azra AlizadDepartment of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, USA.ORCID 0000-0002-7658-1572
Mostafa FatemiDepartment of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, USA.
Mayo Clinic · USMayo Clinic in Florida · US

Funding

Ultrasonic Techniques for Bladder Compliance MeasurementR01DK099231 · NIDDK · MAYO CLINIC ROCHESTER · PI FATEMI, MOSTAFA · 2013 to 2016
$979k
NIDDK NIH HHS R01 DK099231
6 · The paper itself

Abstract

Ultrasound measurements of detrusor muscle thickness have been proposed as a diagnostic biomarker in patients with bladder overactivity and voiding dysfunction. In this study, we present an approach based on deep learning (DL) and dynamic programming (DP) to segment the bladder sac and measure the detrusor muscle thickness from transabdominal 2D B-mode ultrasound images. To assess the performance of our method, we compared the results of automated methods to the manually obtained reference bladder segmentations and wall thickness measurements of 80 images obtained from 11 volunteers. It takes less than a second to segment the bladder from a 2D B-mode image for the DL method. The average Dice index for the bladder segmentation is 0.93 ± 0.04 mm, and the average root-mean-square-error and standard deviation for wall thickness measurement are 0.7 ± 0.2 mm, which is comparable to the manual ground truth. The proposed fully automated and fast method could be a useful tool for segmentation and wall thickness measurement of the bladder from transabdominal B-mode images. The computation speed and accuracy of the proposed method will enable adaptive adjustment of the ultrasound focus point, and continuous assessment of the bladder wall during the filling and voiding process of the bladder.

Indexed as

Specimen HandlingUrinary BladderAutomationHumansUltrasonographybladder segmentationdeep learningdetrusor muscle thicknessdynamic programmingtransabdominal ultrasound

Identifiers

PMID32727146
PMCPMC7436043
OpenAlexW3043921577

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.