Evidence map›Paper›PMID 32725431›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2021

Mechanical performance and implications on bone healing of different screw configurations for plate fixation of diaphyseal tibia fractures: a computational study.

Francesco Travascio, Leonard T Buller, Edward Milne, Loren Latta

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.0field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 20 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Biomechanics of PHILOS plates in Vancouver B1 periprosthetic femoral fracture.Frontiers in bioengineering and biotechnology · 2023
    Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Francesco TravascioDepartment of Mechanical and Aerospace Engineering, University of Miami, 1251 Memorial Drive, Mc Arthur Engineering Building #276, Coral Gables, FL, USA. f.travascio@miami.edu.
Leonard T BullerDepartment of Orthopaedic Surgery, Indiana University School of Medicine, Indianapolis, IN, USA.
Edward MilneMax Biedermann Institute for Biomechanics at Mount Sinai, Miami Beach, FL, USA.
Loren LattaDepartment of Orthopaedic Surgery, University of Miami, Miami, FL, USA.
University of Miami · USIndiana University – Purdue University Indianapolis · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Diaphyseal tibia fractures may require plate fixation for proper healing to occur. Currently, there is no consensus on the number of screws required for proper fixation or the optimal placement of the screws within the plate. Mechanical stability of the construct is a leading criterion for choosing plate and screws configuration. However, number and location of screws have implications on the mechanical environment at the fracture site and, consequently, on bone healing response: The interfragmentary motion attained with a specific plate and screw construct may elicit mechano-transduction signals influencing cell-type differentiation, which in turn affects how well the fracture heals. This study investigated how different screw configurations affect mechanical performance of a tibia plate fixation construct. Three configurations of an eight-hole plate were considered with the fracture in the center of the plate: eight screws-screws at first, fourth, fifth and eighth hole and screws at first, third, sixth and eighth hole. Constructs' stiffness was compared through biomechanical tests on bone surrogates. A finite element model of tibia diaphyseal fracture was used to conduct a stress analysis on the implanted hardware. Finally, the potential for bone regeneration of each screw configuration was assessed via the computational model through the evaluation of the magnitude of mechano-transduction signals at the bone callus. The results of this study indicate that having screws at fourth and fifth holes represents a preferable configuration since it provides mechanical properties similar to those attained by the stiffest construct (eight screws), and elicits an ideal bone regenerative response.

Indexed as

Bone PlatesBone ScrewsFracture Fixation, InternalBiomechanical PhenomenaBone RegenerationFinite Element AnalysisFracture HealingHumansImaging, Three-DimensionalModels, AnatomicModels, TheoreticalTibiaTibial FracturesTomography, X-Ray ComputedBiphasicBone repairFinite element analysisMechanical stimuli indexMechano-transduction

Identifiers

PMID32725431
OpenAlexW3046019892

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.