ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2021
Mechanical performance and implications on bone healing of different screw configurations for plate fixation of diaphyseal tibia fractures: a computational study.
Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 20 citations in OpenAlex.
- Computational models for predicting bone fracture healing: a review of modeling approaches, predictions, and emerging strategies.Biomechanics and modeling in mechanobiology · 2026Review
- An exploration into the principles and theoretical progress of fracture treatment based on the mechanism of fracture healing.Biomaterials translational · 2025Review
- Effects of different reduction patterns on stress distribution in patients with intertrochanteric fractures with intramedullary nail fixation: a finite element analysis.Frontiers in bioengineering and biotechnology · 2025Article
- Biomechanical study between percutaneous vertebroplasty combined with cement pedicle plasty improves vertebral biomechanical stability: A finite element analysis.BMC musculoskeletal disorders · 2024Article
- SSDL-an automated semi-supervised deep learning approach for patient-specific 3D reconstruction of proximal femur from QCT images.Medical & biological engineering & computing · 2024Article
- Biomechanical analysis of the tandem spinal external fixation in a multiple-level noncontiguous lumbar fractures model: a finite element analysis.Frontiers in bioengineering and biotechnology · 2024Article
- Novel screw-cable integrated system(SCIS) for minimally invasive treatment of patella transverse fractures: a finite element analysis.Journal of orthopaedic surgery and research · 2023Article
- Candy box technique for the fixation of inferior pole patellar fractures: finite element analysis and biomechanical experiments.BMC musculoskeletal disorders · 2023Article
- Biomechanics of PHILOS plates in Vancouver B1 periprosthetic femoral fracture.Frontiers in bioengineering and biotechnology · 2023Article
- Biomechanical comparison of intramedullary nail and plate osteosynthesis for extra-articular proximal tibial fractures with segmental bone defect.Frontiers in bioengineering and biotechnology · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Diaphyseal tibia fractures may require plate fixation for proper healing to occur. Currently, there is no consensus on the number of screws required for proper fixation or the optimal placement of the screws within the plate. Mechanical stability of the construct is a leading criterion for choosing plate and screws configuration. However, number and location of screws have implications on the mechanical environment at the fracture site and, consequently, on bone healing response: The interfragmentary motion attained with a specific plate and screw construct may elicit mechano-transduction signals influencing cell-type differentiation, which in turn affects how well the fracture heals. This study investigated how different screw configurations affect mechanical performance of a tibia plate fixation construct. Three configurations of an eight-hole plate were considered with the fracture in the center of the plate: eight screws-screws at first, fourth, fifth and eighth hole and screws at first, third, sixth and eighth hole. Constructs' stiffness was compared through biomechanical tests on bone surrogates. A finite element model of tibia diaphyseal fracture was used to conduct a stress analysis on the implanted hardware. Finally, the potential for bone regeneration of each screw configuration was assessed via the computational model through the evaluation of the magnitude of mechano-transduction signals at the bone callus. The results of this study indicate that having screws at fourth and fifth holes represents a preferable configuration since it provides mechanical properties similar to those attained by the stiffest construct (eight screws), and elicits an ideal bone regenerative response.