Evidence map›Paper›PMID 32725360›Full record

ArticleJournal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing2021

Transseptal use of high-density grid catheter for VT mapping and retrograde hemodynamic support with Impella pump in presence of Mitraclips.

Fuad Hasan, Atisha Khan, Dirk Bandorski, Melchior Seyfarth, Markus Zarse, Bernd Lemke, Harilaos Bogossian

Abstract readCase Reports
PubMed Publisher
In one paragraph

Article in Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 48% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. [How-to case report].Herzschrittmachertherapie & Elektrophysiologie · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Fuad HasanMärkische Kliniken GmbH, Department of Cardiology, Electrophysiology and Angiology, Klinikum Lüdenscheid, Lüdenscheid, Germany.ORCID http://orcid.org/0000-0001-6247-1375
Atisha KhanMärkische Kliniken GmbH, Department of Cardiology, Electrophysiology and Angiology, Klinikum Lüdenscheid, Lüdenscheid, Germany.
Dirk BandorskiMärkische Kliniken GmbH, Department of Cardiology, Electrophysiology and Angiology, Klinikum Lüdenscheid, Lüdenscheid, Germany.
Melchior SeyfarthDepartment of Cardiology, Helios Klinikum Wuppertal, Wuppertal, Germany.
Markus ZarseMärkische Kliniken GmbH, Department of Cardiology, Electrophysiology and Angiology, Klinikum Lüdenscheid, Lüdenscheid, Germany.
Bernd LemkeMärkische Kliniken GmbH, Department of Cardiology, Electrophysiology and Angiology, Klinikum Lüdenscheid, Lüdenscheid, Germany.
Harilaos BogossianDepartment of Cardiology, Witten/Herdecke University, Witten, Germany. bogossian@t-online.de.
Klinikum Lüdenscheid · DEWitten/Herdecke University · DEFernUniversität in Hagen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeWe sought to establish the technical feasibility of VT-mapping with high-density catheters in patients with Mitraclips, requiring a hemodynamic support.

methodsA 73-year-old man with ischemic cardiomyopathy and reduced left ventricular ejection fraction (LVEF ~ 20%) was presented due to syncope and adequate shock of his ICD. Due to severe mitral valve regurgitation (MR), two Mitraclips were implanted earlier. The decision for catheter ablation was made in line with current guidelines. Given the increased PAAINESD score, the use of hemodynamic support was required. To employ an Impella pump via the retrograde transaortic approach, LV-mapping and VT-ablation were necessary to be performed via the transseptal approach, which was challenging due to the presence of Mitraclips. The MV passage with the steerable sheath was guided by a quadripolar catheter and 3D transoesophageal echo (TEE). After the 12F steerable sheath had passed the MV, the quadripolar catheter was exchanged by a high-density (HD) Grid® catheter. Hereafter, the Impella pump was placed retrogradely in the LV, and voltage-mapping of the LV and ablation was performed.

resultsAt the end of the procedure, the Impella pump could be removed in stable hemodynamic conditions. The follow-up after 3, 6, and 12 months showed no new VT episodes.

conclusionsThis case demonstrates the feasibility of the transseptal approach of VT mapping used HD Grid catheter and retrograde hemodynamic support with Impella Pump for VT treatment in patients after Mitraclips implantation. To avoid a damage of the MV and Mitraclips, 3D-TEE is advisable.

Indexed as

Catheter AblationTachycardia, VentricularAgedCathetersHemodynamicsHumansMaleStroke VolumeTreatment OutcomeVentricular Function, LeftHD GridImpella pumpMitraclipsVT ablation

Identifiers

PMID32725360
OpenAlexW3045534474

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.