Evidence map›Paper›PMID 32715084›Full record

ArticleACS biomaterials science & engineering2020

In Vitro/Ex Vivo Investigation of Modified Utah Electrode Array to Selectively Sense and Pace the Sub-Surface Cardiac His Bundle.

Ankur R Shah, Muhammad S Khan, Annie M Hirahara, Matthias Lange, Ravi Ranjan, Derek J Dosdall

Open access · greenAbstract read
In one paragraph

Article in ACS biomaterials science & engineering, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.3field-weighted citation impact, top 50% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Ankur R ShahDepartment of Biomedical Engineering, The University of Utah, Salt Lake City, UT 84112, USA.
Muhammad S KhanNora Eccles Harrison Cardiovascular Research and Training Institute, The University of Utah, Salt Lake City, UT 84112, USA.
Annie M HiraharaDepartment of Biomedical Engineering, The University of Utah, Salt Lake City, UT 84112, USA.
Matthias LangeNora Eccles Harrison Cardiovascular Research and Training Institute, The University of Utah, Salt Lake City, UT 84112, USA.
Ravi RanjanDepartment of Biomedical Engineering, The University of Utah, Salt Lake City, UT 84112, USA.
Derek J DosdallDepartment of Biomedical Engineering, The University of Utah, Salt Lake City, UT 84112, USA.
University of Utah · US

Funding

His-Purkinje Pacing for Low Energy Implantable Cardioverter DefibrillatorsR01HL128752 · NHLBI · UNIVERSITY OF UTAH · PI DOSDALL, DEREK J · 2015 to 2024
$5.0M
Myocardial Substrate Driven Mechanistic Insights into Atrial FibrillationR01HL142913 · NHLBI · UNIVERSITY OF UTAH · PI RANJAN, RAVI · 2018 to 2021
$2.4M
NHLBI NIH HHS R01 HL128752NHLBI NIH HHS R01 HL142913
6 · The paper itself

Abstract

Utah Electrode Arrays (UEAs) have previously been characterized and implanted for neural recordings and stimulation at relatively low current levels. This proof-of-concept study investigated the applicability of UEAs in sub-surface cardiac pacing, for the first time, particularly to selectively sense and pace the His-Bundle (HB). HB pacing produces synchronous ventricular depolarization and improved cardiac function. Modified UEAs with sputtered iridium oxide film (SIROF) tips (100 - 150 μm) were characterized for SIROF delamination using an electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM), and voltage transient (VT) techniques at various current levels of up to 8 mA for a biphasic pulse with 1 ms duration per phase at 4 Hz. Our results indicate that at a short pacing duration of 20 s with current levels of up to 4 mA, the SIROF exhibited a strong charge-transfer performance. For the longer pacing duration (6 min), SIROF demonstrated its holding capacity at all current levels except for ≥2 mA when delamination commenced for the time exceeded 4 min (EIS) and 2 min (VT). UEAs were inserted in isolated, perfused goat hearts to record the HB electrograms in real-time. Both stimulated and unstimulated electrodes were characterized for SIROF delamination before, during and after in vivo work. Our findings indicate that UEA was stable during the heart's contraction and relaxation phase. Further, at a short pacing duration with current levels of up to 4 mA, UEA demonstrated high selectively in sensing the HB. This proof-of-concept work demonstrates the potential applicability of UEAs in cardiac applications.

Indexed as

Bundle of HisElectrodes, ImplantedMicroscopy, Electron, ScanningUtahCardiacElectrochemical impedance spectroscopyHis BundleScanning electron microscopySensingUtah Electrode Array

Identifiers

PMID32715084
PMCPMC7380681
OpenAlexW3022296250

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.