ArticleAsia Oceania journal of nuclear medicine & biology2020
Improvement of diagnostic accuracy of Parkinson's disease on I-123-ioflupane single photon emission computed tomography (
Article in Asia Oceania journal of nuclear medicine & biology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 1 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesI-123-ioflupane single photon emission computed tomography (FP-CIT-SPECT) has been used to assess dopamine transporter (DAT) loss in Parkinson's disease. The specific binding ratio (SBR), a quantitative parameter of DAT density in the striatum, may be affected by differences in age, sex, and SPECT system. The purpose of this study was to evaluate the utility of FP-CIT-SPECT using the Japanese normal database (NDB) in the diagnosis of Parkinson's disease.
methodsTo standardize the quantitative outcome measures of DAT density obtained with different SPECT systems, striatal phantoms filled with striatal to background materials at ratios between 8:1 and 1:1 were measured using a gamma camera (ECAM) in our institute. Consecutive fifty patients (23 men and 27 women; age range, 40-86 years) with suspected PD undergoing FP-CIT SPECT brain imaging during the period from April to October 2016 were enrolled in this retrospective study. Their final diagnoses were PD in 28 patients and PD in 22 patients. SBRs of the patients were calculated using either new (Japanese database with different age and sex; NEWver) or old (non-Japanese database not specifying age and sex; OLDver) version software (AZE Virtual Place Hayabusa [DaTView], AZE, Ltd. Tokyo, Japan). The McNemar test was used to compare the diagnostic accuracy between old and new versions.
resultsBased on the phantom study, the calibrated SBR could be calculated by Y=1.25×Measured SBR+0.78. The sensitivities for OLDver and NEWver were 100% and 93%, respectively (p=0.5), and the specificities were 55% and 100% (p=0.002). The diagnostic accuracy of NEWver (96%) was better than that of OLDver (80%, p<0.001).
conclusionFP-CIT-SPECT using the Japanese NDB improved the diagnostic accuracy of PD by improving specificity.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.