Evidence map›Paper›PMID 32709217›Full record

ArticleBMC bioinformatics2020

METROID: an automated method for robust quantification of subcellular fluorescence events at low SNR.

Marcelo Zoccoler, Pedro X de Oliveira

Abstract read
In one paragraph

Article in BMC bioinformatics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Marcelo ZoccolerDepartment of Biomedical Engineering (DEB), School of Electrical and Computer Engineering, University of Campinas, 400, Albert Einstein Avenue, Campinas, SP, 13083-852, Brazil. marzoccoler@gmail.com.ORCID http://orcid.org/0000-0002-6165-4679
Pedro X de OliveiraDepartment of Biomedical Engineering (DEB), School of Electrical and Computer Engineering, University of Campinas, 400, Albert Einstein Avenue, Campinas, SP, 13083-852, Brazil.

Funding

Fundação de Amparo à Pesquisa do Estado de São Paulo Proc. N 2011/51199-6
6 · The paper itself

Abstract

backgroundIn cell biology, increasing focus has been directed to fast events at subcellular space with the advent of fluorescent probes. As an example, voltage sensitive dyes (VSD) have been used to measure membrane potentials. Yet, even the most recently developed genetically encoded voltage sensors have demanded exhausting signal averaging through repeated experiments to quantify action potentials (AP). This analysis may be further hampered in subcellular signals defined by small regions of interest (ROI), where signal-to-noise ratio (SNR) may fall substantially. Signal processing techniques like blind source separation (BSS) are designed to separate a multichannel mixture of signals into uncorrelated or independent sources, whose potential to separate ROI signal from noise has been poorly explored. Our aims are to develop a method capable of retrieving subcellular events with minimal a priori information from noisy cell fluorescence images and to provide it as a computational tool to be readily employed by the scientific community.

resultsIn this paper, we have developed METROID (Morphological Extraction of Transmembrane potential from Regions Of Interest Device), a new computational tool to filter fluorescence signals from multiple ROIs, whose code and graphical interface are freely available. In this tool, we developed a new ROI definition procedure to automatically generate similar-area ROIs that follow cell shape. In addition, simulations and real data analysis were performed to recover AP and electroporation signals contaminated by noise by means of four types of BSS: Principal Component Analysis (PCA), Independent Component Analysis (ICA), and two versions with discrete wavelet transform (DWT). All these strategies allowed for signal extraction at low SNR (- 10 dB) without apparent signal distortion.

conclusionsWe demonstrate the great capability of our method to filter subcellular signals from noisy fluorescence images in a single trial, avoiding repeated experiments. We provide this novel biomedical application with a graphical user interface at https://doi.org/10.6084/m9.figshare.11344046.v1 , and its code and datasets are available in GitHub at https://github.com/zoccoler/metroid .

Indexed as

Signal-To-Noise RatioSoftwareAlgorithmsAnimalsAutomationColoring AgentsComputer SimulationFluorescenceHumansMembrane PotentialsPrincipal Component AnalysisRatsSignal Processing, Computer-AssistedSubcellular FractionsUser-Computer InterfaceColoring AgentsBlind source separationFluorescence imagesIndependent component analysisROI generationVoltage sensitive dyes

Identifiers

PMID32709217
PMCPMC7379836

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.