Evidence map›Paper›PMID 32708486›Full record

ArticleNanomaterials (Basel, Switzerland)2020

Troponin Aptamer on an Atomically Flat Au Nanoplate Platform for Detection of Cardiac Troponin I.

Hyoban Lee, Hyungjun Youn, Ahreum Hwang, Hyunsoo Lee, Jeong Young Park, Weon Kim, Youngdong Yoo, Changill Ban, Taejoon Kang, Bongsoo Kim

Open access · goldAbstract read
In one paragraph

Article in Nanomaterials (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.7field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 28 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
  4. Review
  5. Article
  6. Review
  7. Review
  8. Review
  9. Review
  10. Review
  11. Review
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 5 institutions in 1 country.

Hyoban LeeDepartment of Chemistry, KAIST, Daejeon 34141, Korea.
Hyungjun YounDepartment of Chemistry, POSTECH, Pohang 37673, Korea.
Ahreum HwangDepartment of Chemistry, KAIST, Daejeon 34141, Korea.
Hyunsoo LeeDepartment of Chemistry, KAIST, Daejeon 34141, Korea.
Jeong Young ParkDepartment of Chemistry, KAIST, Daejeon 34141, Korea.
Weon KimDivision of Cardiology, Department of Internal Medicine, Kyung Hee University Hospital, Kyung Hee University, Seoul 02447, Korea.
Youngdong YooDepartment of Chemistry, Ajou University, Suwon 16499, Korea.ORCID 0000-0002-2916-2738
Changill BanDepartment of Chemistry, POSTECH, Pohang 37673, Korea.
Taejoon KangBionanotechnology Research Center, KRIBB, Daejeon 34141, Korea.ORCID 0000-0002-5387-6458
Bongsoo KimDepartment of Chemistry, KAIST, Daejeon 34141, Korea.
Korea Advanced Institute of Science and Technology · KRPohang University of Science and Technology · KRAjou University · KRKorea Research Institute of Bioscience and Biotechnology · KRKyung Hee University · KR

Funding

National Research Foundation of Korea H-GUARD_2013M3A6B2078950National Research Foundation of Korea NRF-2018M3A9E2022821National Research Foundation of Korea NRF-2019R1C1C1006867
6 · The paper itself

Abstract

Well-ordered bioreceptors on atomically flat Au surfaces can be a high-performance biosensor. Cardiac troponin I proteins (cTnIs) have been regarded as a specific biomarker for acute myocardial infarction (AMI). Here, we report the accurate detection of cTnIs using an aptamer-immobilized Au nanoplate platform. The single-crystalline and atomically flat Au nanoplate was characterized by atomic force microscopy. For the precise detection of cTnI, we immobilized an aptamer that can strongly bind to cTnI onto an atomically flat Au nanoplate. Using the aptamer-immobilized Au nanoplate, cTnIs were successfully detected at a concentration of 100 aM (2.4 fg/mL) in buffer solution. Furthermore, cTnIs in serum could be identified at a concentration of 100 fM (2.4 pg/mL). The total assay time was ~7 h. Importantly, the aptamer-immobilized Au nanoplate enabled us to diagnose AMI patients accurately, suggesting the potential of the present method in the diagnosis of AMI.

Indexed as

aptamercTnInanoplatesurface-enhanced Raman scattering

Identifiers

PMID32708486
PMCPMC7407982
OpenAlexW3042693036

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.