Evidence map›Paper›PMID 32705423›Full record

ArticleAnnals of biomedical engineering2021

Structural Responses of Integrated Parametric Aortic Valve in an Electro-Mechanical Full Heart Model.

Adi Morany, Karin Lavon, Danny Bluestein, Ashraf Hamdan, Rami Haj-Ali

Open access · greenAbstract read
In one paragraph

Article in Annals of biomedical engineering, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.9field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Adi MoranySchool of Mechanical Engineering, Faculty of Engineering, Tel Aviv University, Tel Aviv, Ramat Aviv, 69978, Israel.
Karin LavonSchool of Mechanical Engineering, Faculty of Engineering, Tel Aviv University, Tel Aviv, Ramat Aviv, 69978, Israel.
Danny BluesteinDepartment of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8151, USA.
Ashraf HamdanDepartment of Cardiology, Rabin Medical Center, Petach Tikva, 4941492, Israel.
Rami Haj-AliSchool of Mechanical Engineering, Faculty of Engineering, Tel Aviv University, Tel Aviv, Ramat Aviv, 69978, Israel. rami98@tau.ac.il.
Tel Aviv University · ILRabin Medical Center · ILStony Brook University · US

Funding

Biomechanical Approaches and Technologies for Enhancing TAVR OutcomesU01EB026414 · NIBIB · STATE UNIVERSITY NEW YORK STONY BROOK · PI BLUESTEIN, DANNY · 2018 to 2022
$3.8M
NIBIB NIH HHS U01 EB026414NIH HHS EB026414
6 · The paper itself

Abstract

The aortic valve (AV) is located between the left ventricle and the aorta and responsible for maintaining an outward unidirectional flow. Many AV hemodynamic and structural aspects of have been extensively studied, however, more sophisticated models are needed to better understand the AV biomechanical behavior. This study deals with integrating a new parametric AV structural model with the electro-mechanical Living Heart Human Model® (LHHM). The LHHM is a finite element model simulating human heart capable of realistic electro-mechanical simulations. Different geometric metrics of AV have been examined. New integrated structural AV model within the LHHM better predict local stresses during the cardiac cycle due to the realistic boundary condition derived from the LHHM. It was found that ellipticity index (EI), calculated as the ratio between the maximal (Max) and minimal (Min) aortic annulus (AA) diameters, well correlates with measured clinical data obtained from patients undergoing computed tomography (CT) while the annular perimeter (Perim) matches the same trend. This increases the confidence in the predicted kinematic behavior, leaflets coaptation, and the overall stresses. From the clinical aspect, the new proposed coupled and integrated AV modeling can serve as a platform for design and implementation of pre-transcatheter aortic valve replacement (TAVR) procedures.

Indexed as

Models, CardiovascularAdultBiomechanical PhenomenaComputed Tomography AngiographyComputer SimulationFinite Element AnalysisHeartHumansMaleStress, MechanicalAortic valve electro-mechanical responseDynamic aortic valve biomechanicsFinite element analysisLiving Heart Human ModelStresses prediction

Identifiers

PMID32705423
PMCPMC7775292
OpenAlexW3044295876

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.