ArticleTranslational vision science & technology2020
Testing a Novel Device for Accurate Ultrasound Delivery During Crystalline Lens Phacoemulsification Surgery.
Article in Translational vision science & technology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Surgical Efficiency Comparison Between Two Phacoemulsification Systems.Clinical ophthalmology (Auckland, N.Z.) · 2024Article
- Phacoemulsification Tip Elongation Under Standardized Resistance: An Objective Measure of Human Crystalline Lens Hardness.Translational vision science & technology · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: To assess whether the use of a patented, novel feedback device intended to accurately control phacoemulsification tip elongation is effective under varying machine settings and material resistance. Methods: Sculpt mode phaco (550-mm Hg Venturi pump; elongations, 35 and 70 µm) and quadrant settings (550-mm Hg Venturi pump; elongations, 15, 30, and 60 µm) were used in agar gel of incremental density (1%, 2%, 3%, and 6% in demineralized water). Dispersed lens fragments were also simulated with 6% agar gel spherules (2-5 mm in diameter; 550-mm Hg vacuum, and 60-µm elongation). Actual phaco tip elongation was measured on voltage readings from the piezoelectric crystals and compared to nominal elongation with feedback control off and on. Results: Mismatch between nominal and actual elongation when feedback control was off in sculpt mode varied between -13.51 µm and -23.07 µm of nominal elongation; in quadrant mode, mismatch varied between -2.79 µm and -20.41 µm. When the feedback control system was switched on, mismatch varied between -0.02 µm and +0.43 µm ( Conclusions: A novel feedback control system effectively controls elongation accuracy regardless of the resistance offered by incremental agar gel concentrations. Translational Relevance: Implementing feedback control in phaco handpieces dramatically improves surgical accuracy. The translational value of this research relies on its immediate applicability to routine cataract surgery, resulting in a more appropriate use of ultrasound energy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.