Evidence map›Paper›PMID 32704426›Full record

ArticleTranslational vision science & technology2020

Optimization of the Light Sword Lens for Presbyopia Correction.

Walter Torres-Sepúlveda, Alejandro Mira-Agudelo, John Fredy Barrera-Ramírez, Krzysztof Petelczyc, Andrzej Kolodziejczyk

Open access · goldAbstract read
In one paragraph

Article in Translational vision science & technology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.7field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 8 citations in OpenAlex.

  1. Presbyopia Correction in Lens Replacement Surgery: A Review.Clinical & experimental ophthalmology · 2025
    Review
  2. Article
  3. The effects of premium intraocular lenses on presbyopia treatments.Advances in ophthalmology practice and research
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Walter Torres-SepúlvedaGrupo de Óptica y Fotónica, Instituto de Física, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín, Colombia.
Alejandro Mira-AgudeloGrupo de Óptica y Fotónica, Instituto de Física, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín, Colombia.
John Fredy Barrera-RamírezGrupo de Óptica y Fotónica, Instituto de Física, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín, Colombia.
Krzysztof PetelczycFaculty of Physics, Warsaw University of Technology, Koszykowa 75, 00-662, Warszawa, Poland.
Andrzej KolodziejczykFaculty of Physics, Warsaw University of Technology, Koszykowa 75, 00-662, Warszawa, Poland.
Universidad de Antioquia · COWarsaw University of Technology · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: We propose and evaluate the modifications of a light sword lens (LSL) to obtain better performance for distance vision while maintaining good operation for near and intermediate vision. Methods: The modifications consisted of assigning angular or circular windows for distance vision while rescaling the LSL profile in the remaining area of the element. The objective performance of the redesigned LSLs was verified numerically by the Strehl ratio and experimentally using correlation coefficients and Michelson contrast. Subjective assessments were provided by monocular visual acuity (VA) and contrast sensitivity (CS) through-focus curves for six patients with paralyzed accommodation. The tested object vergence range was [-4.0, 0.0] diopters (D). All experiments were conducted in a custom-made monocular visual simulator. Results: Computational simulations and objective experiments confirmed the better performance of the modified LSL for the imaging of distant objects. The proposed angular and radial modulations resulted in flat VA and CS through-focus curves, indicating more uniform quality of vision with clearly improved distance vision. The VA provided by the modified LSL profiles showed a maximal improvement of 1.5 lines of acuity with respect to the VA provided by the conventional LSL at distance vision. Conclusions: Optimized LSLs provide better imaging of distant objects while maintaining a large depth of focus. This results in comparable and acceptable quality for distance, intermediate, and near vision. Therefore, the modified LSLs appear to be promising presbyopia correctors. Translational Relevance: The new design of LSL reveals an improved performance for all ranges of vision and becomes a promissory element for a real presbyopia correction in clinical applications.

Indexed as

Lens, CrystallineLenses, IntraocularPresbyopiaContrast SensitivityHumansVisual Acuityoptical corrections and treatmentspresbyopiapsychophysical assessmentvisual optics

Identifiers

PMID32704426
PMCPMC7347505
OpenAlexW3005789742

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.