Evidence map›Paper›PMID 32699760›Full record

ArticleInternational journal of spine surgery2020

Effect of Instrument Navigation on C-arm Radiation and Time during Spinal Procedures: A Clinical Evaluation.

Timothy Y Wang, Farah Hamouda, Vikram A Mehta, Eric W Sankey, Chester Yarbrough, Robert Lark, Muhammad M Abd-El-Barr

Abstract read
In one paragraph

Article in International journal of spine surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Timothy Y WangDuke University Medical Center, Department of Neurological Surgery, Durham, North Carolina.
Farah HamoudaTrackX Technology, LLC, Chapel Hill, North Carolina.
Vikram A MehtaDuke University Medical Center, Department of Neurological Surgery, Durham, North Carolina.
Eric W SankeyDuke University Medical Center, Department of Neurological Surgery, Durham, North Carolina.
Chester YarbroughDuke University Medical Center, Department of Neurological Surgery, Durham, North Carolina.
Robert LarkDuke University Medical Center, Department of Neurological Surgery, Durham, North Carolina.
Muhammad M Abd-El-BarrDuke University Medical Center, Department of Neurological Surgery, Durham, North Carolina.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionAs minimally invasive spine surgery gains popularity, a focused effort must be made to reduce intraoperative radiation exposure to levels as low as reasonably achievable. Here, we demonstrate the clinical efficacy of a novel technology to aid in instrument navigation that aims to reduce intraoperative radiation exposure, number of fluoroscopic images, and time required to perform the most radiation intensive portions of a multitude of spinal procedures.

methodsAn internally randomized controlled study was performed over a 1-month period in order to clinically evaluate the effect of the C-arm assisted instrument tracking system, TrackX, on surgeon workflow, time, and radiation emitted. Three surgeons performed multiple spinal procedures on a total of 10 study patients and an additional 3 control patients. The surgeries encompassed minimally invasive spinal techniques and spanned extreme lateral interbody fusion, oblique lumbar interbody fusion, transforaminal lumbar interbody fusion along with percutaneous iliac screw placement, hardware removal, and kyphoplasty. The tasks studied included skin marking, first dilator insertion, localization for hardware placement and hardware removal.

resultsOverall radiation reduction was 83% (

conclusionsTrackX instrument navigation is a clinically efficacious and accurate instrument tracking modality. This is the first instrument navigational technology that reduces radiation exposure and images required to complete a procedure while decreasing operative time. TrackX thus allows increased surgical efficiency while increasing operative efficiency and improving intraoperative safety. LEVEL OF EVIDENCE: 2.

Indexed as

C-armfluoroscopyimage guided surgeryinstrument trackingminimally invasive surgerynavigationradiationspinetime

Identifiers

PMID32699760
PMCPMC7343269

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.