Evidence map›Paper›PMID 32698908›Full record

ArticleKnee surgery & related research2020

Polyethylene spinout in the Attune® Cruciate-Retaining Rotating-Platform (CR RP) total knee arthroplasty performed with a cruciate-sacrificing and measured-resection technique.

Cillian J Keogh, David Mulcahy, Declan Reidy, David E Beverland, James A Harty

Registry-linked trialAbstract read
In one paragraph

Article in Knee surgery & related research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06483178 (A Randomised Controlled Trial Comparing Gait in Fixed or Rotating Cementless Total Knee Arthroplasties), which is not on this map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06483178 nanot yet recruitingnot on this mapstarted 2025, after this paper: background citation

A Randomised Controlled Trial Comparing Gait in Fixed or Rotating Cementless Total Knee Arthroplasties

TypeinterventionalSponsorBelfast Health and Social Care TrustRan2025 to 2027Enrolled90ConditionsTotal Knee Arthroplasty, Knee OsteoarthritisArmsAttune knee implant, Triathlon knee implant
3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Observational
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Cillian J KeoghDepartment of Trauma and Orthopaedic Surgery, Cork University Hospital/South Infirmary Victoria University Hospital, Wilton, Cork, T12 DC4A, Republic of Ireland. cilliankeogh5@gmail.com.
David MulcahyDepartment of Orthopaedic Surgery, Bon Secours Hospital Cork, College Road, Cork, Republic of Ireland.
Declan ReidyDepartment of Trauma and Orthopaedic Surgery, Cork University Hospital/South Infirmary Victoria University Hospital, Wilton, Cork, T12 DC4A, Republic of Ireland.
David E BeverlandMusgrave Park Hospital, Stockman's Lane, Belfast, BT9 7JB, Northern Ireland, UK.
James A HartyDepartment of Trauma and Orthopaedic Surgery, Cork University Hospital/South Infirmary Victoria University Hospital, Wilton, Cork, T12 DC4A, Republic of Ireland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionPolyethylene (PE) spinout is a known but uncommon complication when using a mobile-bearing (MB) total knee arthroplasty (TKA) design. Sacrificing the posterior cruciate ligament (PCL) is within the manufacturer's recommendations for the Attune® Cruciate-Retaining Rotating-Platform (CR RP) knee design.

aimTo discuss the potential aetiology and prevention of spinout in the Attune® CR RP knee.

methodsWe used a retrospective radiological review from two centres reporting a higher rate of spinout in the Attune® CR RP knee using a cruciate-sacrificing and measured-resection technique when compared to a gap-balancing technique. Three hundred and thirty-two patients were evaluated over a 3-year period.

resultsThere were 8 out of 279 (2.86%) cases of spinout in our first cohort of patients using a measured-resection technique. There were 0 out of 53 cases of spinout in our second cohort of patients where a gap-balancing technique was used. One spinout was reduced closed, the other seven were initially revised to a thicker RP insert of the same design. Of these seven, three underwent a further revision TKA and one patient required a knee fusion/arthrodesis.

conclusionsThis study reports a higher incidence of PE spinout in the Attune® CR RP TKA when a measured-resection technique in combination with PCL resection is performed. We recommend a gap-balancing technique with conservative soft-tissue release if the surgeon is planning to sacrifice the PCL in the Attune® CR RP.

Indexed as

Attune®BalancingCruciateGapLCS®PlatformPolyethyleneRetainingRotatingSpinout

Identifiers

PMID32698908
PMCPMC7374844

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.