Evidence map›Paper›PMID 32697867›Full record

ArticleMagnetic resonance in medicine2020

A variable resolution approach for improved acquisition of hyperpolarized

Jeremy W Gordon, Adam W Autry, Shuyu Tang, Jasmine Y Graham, Robert A Bok, Xucheng Zhu, Javier E Villanueva-Meyer, Yan Li, Michael A Ohilger, Maria Roselle Abraham and 3 more

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 39 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
39citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

39 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Review
  4. Article
  5. Clinical Translation of HyperpolarizedAJNR. American journal of neuroradiology · 2025
    Review
  6. Hyperpolarized [1-Journal of magnetic resonance open · 2025
    Article
  7. Article
  8. Article
  9. Quo Vadis HyperpolarizedZeitschrift fur medizinische Physik · 2025
    Review
  10. Hyperpolarized [1-Brain communications · 2025
    Article
  11. Article
  12. Article
  13. A pharmacokinetic model for hyperpolarizedMagnetic resonance in medicine · 2024
    Article
  14. Article
  15. A vendor-neutral EPI sequence for hyperpolarizedMagnetic resonance in medicine · 2024
    Article
  16. Current methods for hyperpolarized [1-Magnetic resonance in medicine · 2024
    Review
  17. Article
  18. Article
  19. Regional quantification of cardiac metabolism with hyperpolarized [1-Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2023
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Jeremy W GordonDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA.ORCID 0000-0003-2760-4886
Adam W AutryDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA.
Shuyu TangDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA.ORCID 0000-0002-9911-482X
Jasmine Y GrahamDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA.ORCID 0000-0002-7259-0332
Robert A BokDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA.
Xucheng ZhuDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA.ORCID 0000-0002-5537-5542
Javier E Villanueva-MeyerDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA.
Yan LiDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA.
Michael A OhilgerDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA.ORCID 0000-0001-6878-8189
Maria Roselle AbrahamDivision of Cardiology, Department of Medicine, University of California San Francisco, San Francisco, California, USA.
Duan XuDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA.
Daniel B VigneronDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA.
Peder E Z LarsonDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA.ORCID 0000-0003-4183-3634

Funding

Project 4: Multi-modality Metabolic Imaging for Monitoring Molecular Sub-types of GliomaP01CA118816 · NCI · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI Pavithra Viswanath · 2007 to 2026
$44.7M
TR&D3: Open-Source Tools for Processing Hyperpolarized MR DataP41EB013598 · NIBIB · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI DUAN XU · 2011 to 2026
$19.9M
Training Program in Translational Brain Tumor ResearchT32CA151022 · NCI · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI Joseph F Costello · 2010 to 2026
$6.6M
Supplement for Development and Translation of Specialized Hyperpolarized C-13 MRI Methods for Alzheimer's DiseaseU01EB026412 · NIBIB · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI GORDON, JEREMY WILLIAM, VIGNERON, DANIEL B · 2019 to 2023
$6.6M
Translating HP 13C MRI as a Novel Paradigm for Assessing Drug Target InhibitionR01CA183071 · NCI · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI HURD, RALPH EUGENE, MUNSTER, PAMELA N. · 2014 to 2018
$3.3M
Hyperpolarized C-13 Diffusion MRI Measures of Cellular Transport and MetabolismR01EB016741 · NIBIB · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI LARSON, PEDER ERIC ZUFALL · 2014 to 2017
$2.0M
NCI NIH HHS P01 CA118816NCI NIH HHS R01 CA183071NCI NIH HHS T32 CA151022NIBIB NIH HHS P41 EB013598NIBIB NIH HHS R01 EB016741NIBIB NIH HHS U01 EB026412
6 · The paper itself

Abstract

purposeTo ameliorate tradeoffs between a fixed spatial resolution and signal-to-noise ratio (SNR) for hyperpolarized

methodsIn MRI, SNR is proportional to voxel volume but retrospective downsampling or voxel averaging only improves SNR by the square root of voxel size. This can be exploited with a metabolite-selective imaging approach that independently encodes each compound, yielding high-resolution images for the injected substrate and coarser resolution images for downstream metabolites, while maintaining adequate SNR for each. To assess the efficacy of this approach, hyperpolarized [1-

resultsCompared with a constant resolution acquisition, variable-resolution data sets showed improved detectability of metabolites in pre-clinical renal studies with a 3.5-fold, 8.7-fold, and 6.0-fold increase in SNR for lactate, alanine, and bicarbonate data, respectively. Variable-resolution data sets from healthy human subjects showed cardiac structure and neuro-vasculature in the higher resolution pyruvate images (6.0 × 6.0 mm

conclusionWe developed a variable-resolution strategy for hyperpolarized

Indexed as

Magnetic Resonance ImagingPyruvic AcidAnimalsCarbon IsotopesRatsRats, Sprague-DawleyRetrospective StudiesSignal-To-Noise RatioCarbon IsotopesPyruvic Acidcarbon-13EPIhyperpolarizationMRIpyruvate

Identifiers

PMID32697867
PMCPMC7719570

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.