In one paragraph

Article in American journal of physiology. Cell physiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
2.0field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 29 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Review
  13. Review
  14. Article
  15. Review
  16. Article
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Jong Hoon ChoiDepartment of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota.
Lorena LoarcaDepartment of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota.
Jose M De Hoyos-VegaDepartment of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota.
Neda DadgarDepartment of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota.ORCID 0000-0003-3220-7148
Kevin LoutherbackDepartment of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota.
Vijay H ShahDivision of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota.ORCID 0000-0001-7620-573X
Gulnaz StybayevaDepartment of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota.
Alexander RevzinDepartment of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota.
Mayo Clinic · US

Funding

PILOT AND FEASIBILTY PROGRAMP30DK084567 · NIDDK · MAYO CLINIC ROCHESTER · PI GREGORY J. GORES · 2009 to 2026
$22.2M
Microsystems for Shaping Stem Cell Fate SelectionsR01DK107255 · NIDDK · UNIVERSITY OF CALIFORNIA AT DAVIS · PI REVZIN, ALEXANDER · 2016 to 2020
$1.8M
NIDDK NIH HHS P30 DK084567NIDDK NIH HHS R01 DK107255NIH HHS DK107255
6 · The paper itself

Abstract

A number of cell culture approaches have been described for maintenance of primary hepatocytes. Forming hepatocytes into three-dimensional (3-D) spheroids is one well-accepted method for extending epithelial phenotype of these cells. Our laboratory has previously observed enhanced function of two-dimensional (2-D, monolayer) hepatocyte cultures in microfluidic devices due to increased production of several hepato-inductive growth factors, including hepatocyte growth factor (HGF). In the present study, we wanted to test a hypothesis that culturing hepatocyte spheroids (3-D) in microfluidic devices will also result in enhanced phenotype and function. To test this hypothesis, we fabricated devices with small and large volumes. Both types of devices included a microstructured floor containing arrays of pyramidal wells to promote assembly of hepatocytes into spheroids with individual diameters of ~100 µm. The hepatocyte spheroids were found to be more functional, as evidenced by higher level of albumin synthesis, bile acid production, and hepatic enzyme expression, in low-volume compared with large-volume devices. Importantly, high functionality of spheroid cultures correlated with elevated levels of HGF secretion. Although decay of hepatic function (albumin secretion) was observed over the course 3 wk, this behavior could be abrogated by inhibiting TGF-β1 signaling. With TGF-β1 inhibitor, microfluidic hepatocyte spheroid cultures maintained high and stable levels of albumin synthesis over the course of 4 wk. To further highlight utility of this culture platform for liver disease modeling, we carried out alcohol injury experiments in microfluidic devices and tested protective effects of interleukin-22: a potential therapy for alcoholic hepatitis.

Indexed as

MicrofluidicsAnimalsCells, CulturedCell SurvivalCoculture TechniquesHepatocytesPhenotypeSpheroids, Cellularalcohol injuryhepatocyte spheroidsmicrofluidic cultures

Identifiers

PMID32697600
PMCPMC7509267
OpenAlexW3044144040

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.