ArticleAmerican journal of physiology. Cell physiology2020
Microfluidic confinement enhances phenotype and function of hepatocyte spheroids.
Article in American journal of physiology. Cell physiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed, 29 citations in OpenAlex.
- Advances in In Vitro Vascularization of Engineered Tissues: From Microvessel Formation to Hepatic Tissue Integration.Regenerative therapy · 2026Article
- Paracrine Factor Local Gradient-Generating System for Engineering Perfusable Vascularized Hepatocyte Tissues with Perfusion-Induced Proliferation.Advanced healthcare materials · 2026Article
- Human Organoids and Organ-on-Chip for Biotoxin Assessment: Applications, Best Practices, and a Translational Roadmap.Toxins · 2026Review
- Multicompartment hydrogel microcapsules for creating spatially patterned cell co-cultures.Microsystems & nanoengineering · 2026Article
- An Ultrathin Coating of Microcapsules Enhances the Function of Encapsulated Hepatocyte Spheroids.ACS applied materials & interfaces · 2024Article
- Article
- Microfluidic 3D hepatic cultures integrated with a droplet-based bioanalysis unit.Biosensors & bioelectronics · 2024Article
- Human Hepatocyte Transplantation: Three Decades of Clinical Experience and Future Perspective.Stem cells translational medicine · 2024Review
- Function of hepatocyte spheroids in bioactive microcapsules is enhanced by endogenous and exogenous hepatocyte growth factor.Bioactive materials · 2023Article
- Article
- A Microfluidic Device for Long-Term Maintenance of Organotypic Liver Cultures.Advanced materials technologies · 2023Article
- Bioengineering liver microtissues for modeling non-alcoholic fatty liver disease.EXCLI journal · 2023Review
- Liver-on-a-chip: Considerations, advances, and beyond.Biomicrofluidics · 2022Review
- Setup of human liver-chips integrating 3D models, microwells and a standardized microfluidic platform as proof-of-concept study to support drug evaluation.Biomaterials and biosystems · 2022Article
- Hepatocyte cultures: From collagen gel sandwiches to microfluidic devices with integrated biosensors.APL bioengineering · 2021Review
- Long-term maintenance of functional primary human hepatocytes in 3D gelatin matrices produced by solution blow spinning.Scientific reports · 2021Article
- In Vitro Miniaturized Tuberculosis Spheroid Model.Biomedicines · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
Abstract
A number of cell culture approaches have been described for maintenance of primary hepatocytes. Forming hepatocytes into three-dimensional (3-D) spheroids is one well-accepted method for extending epithelial phenotype of these cells. Our laboratory has previously observed enhanced function of two-dimensional (2-D, monolayer) hepatocyte cultures in microfluidic devices due to increased production of several hepato-inductive growth factors, including hepatocyte growth factor (HGF). In the present study, we wanted to test a hypothesis that culturing hepatocyte spheroids (3-D) in microfluidic devices will also result in enhanced phenotype and function. To test this hypothesis, we fabricated devices with small and large volumes. Both types of devices included a microstructured floor containing arrays of pyramidal wells to promote assembly of hepatocytes into spheroids with individual diameters of ~100 µm. The hepatocyte spheroids were found to be more functional, as evidenced by higher level of albumin synthesis, bile acid production, and hepatic enzyme expression, in low-volume compared with large-volume devices. Importantly, high functionality of spheroid cultures correlated with elevated levels of HGF secretion. Although decay of hepatic function (albumin secretion) was observed over the course 3 wk, this behavior could be abrogated by inhibiting TGF-β1 signaling. With TGF-β1 inhibitor, microfluidic hepatocyte spheroid cultures maintained high and stable levels of albumin synthesis over the course of 4 wk. To further highlight utility of this culture platform for liver disease modeling, we carried out alcohol injury experiments in microfluidic devices and tested protective effects of interleukin-22: a potential therapy for alcoholic hepatitis.
Indexed as
Identifiers
What OpenQuestion holds