ArticleInternational journal of computer assisted radiology and surgery2020
A visual odometry base-tracking system for intraoperative C-arm guidance.
Article in International journal of computer assisted radiology and surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- Robotic Intraoperative Imaging in Orthopaedic and Trauma Surgery: Initial Clinical Experience With a Self-Driving Mobile 3D C-Arm in the First 300 Cases.The international journal of medical robotics + computer assisted surgery : MRCAS · 2026Article
- [Self-driving, fully motorized C-arm in spinal surgery: a comparative study].Orthopadie (Heidelberg, Germany) · 2026Article
- Efficient intraoral photogrammetry using self-identifying projective invariant marker.International journal of computer assisted radiology and surgery · 2024Article
- [Mobile C-arm-Radiation exposure and workflow killer? : Potential of an innovative assistance system for intraoperative positioning].Unfallchirurgie (Heidelberg, Germany) · 2023Review
- Indoor Localization of Hand-Held OCT Probe Using Visual Odometry and Real-Time Segmentation Using Deep Learning.IEEE transactions on bio-medical engineering · 2022Article
- RAY-POS: a LIDAR-based assistance system for intraoperative repositioning of mobile C-arms without external aids.International journal of computer assisted radiology and surgery · 2022Article
- The effect of artificial X-rays on C-arm positioning performance in a simulated orthopaedic surgical setting.International journal of computer assisted radiology and surgery · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeC-arms are portable X-ray devices used to generate radiographic images in orthopedic surgical procedures. Evidence suggests that scouting images, which are used to aid in C-arm positioning, result in increased operation time and excess radiation exposure. C-arms are also primarily used qualitatively to view images, with limited quantitative functionality. Various techniques have been proposed to improve positioning, reduce radiation exposure, and provide quantitative measuring tools, all of which require accurate C-arm position tracking. While external stereo camera systems can be used for this purpose, they are typically considered too obtrusive. This paper therefore presents the development and verification of a low-profile, real-time C-arm base-tracking system using computer vision techniques.
methodsThe proposed tracking system, called OPTIX (On-board Position Tracking for Intraoperative X-rays), uses a single downward-facing camera mounted to the base of a C-arm. Relative motion tracking and absolute position recovery algorithms were implemented to track motion using the visual texture in operating room floors. The accuracy of the system was evaluated in a simulated operating room mounted on a real C-arm.
resultsThe relative tracking algorithm measured relative translation position changes with errors of less than 0.75% of the total distance travelled, and orientation with errors below 5% of the cumulative rotation. With an error-correction step incorporated, OPTIX achieved C-arm repositioning with translation errors of less than [Formula: see text] mm and rotation errors of less than [Formula: see text]. A display based on the OPTIX measurements enabled consistent C-arm repositioning within 5 mm of a previously stored reference position.
conclusionThe system achieved clinically relevant accuracies and could result in a reduced need for scout images when re-acquiring a previous position. We believe that, if implemented in an operating room, OPTIX has the potential to reduce both operating time and harmful radiation exposure to patients and surgical staff.
Indexed as
Identifiers
32696220What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.