Evidence map›Paper›PMID 32692304›Full record

Observational studyThe neuroradiology journal2020

Endovascular treatment of patients with intracranial aneurysms: feasibility and successful employment of a new low profile visible intraluminal support (LVIS) EVO stent.

Alexander Sirakov, Pervinder Bhogal, Markus Möhlenbruch, Stanimir Sirakov

Abstract readObservational Study
In one paragraph

Observational study in The neuroradiology journal, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Trial
  2. Trial
  3. Article
  4. Review
  5. Observational
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Alexander SirakovRadiology Department, University Hospital Saint Ivan Rilski, Bulgaria.
Pervinder BhogalInterventional Neuroradiology Department, The Royal London Hospital, UK.
Markus MöhlenbruchNeuroradiology Department, Heidelberg University Hospital, Germany.
Stanimir SirakovRadiology Department, University Hospital Saint Ivan Rilski, Bulgaria.ORCID https://orcid.org/0000-0001-6034-5340

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeLow-profile self-expandable stents have increased the number of intracranial aneurysms treated by endovascular means. The new low-profile visible intraluminal support device LVIS EVO (Microvention), the successor of LVIS Jr, is a self-expandable and retrievable microstent system, designed for implantation into intracranial arteries with a diameter up to 2.0 mm. In this retrospective study we aimed to elucidate the technical feasibility and clinical safety of the novel LVIS EVO stent for stent-assisted coil embolisation of intracranial aneurysms. MATERIALS AND

methodsA single centre technical report of the first six consecutive cases of stent-assisted coil embolisation with the novel LVIS EVO stent for the treatment of unruptured or recanalised intracranial aneurysms. Records were made of basic demographics, aneurysmal characteristics, device properties and related technical details, adverse events, clinical outcomes and occlusion rates on available radiological follow-up.

resultsSix LVIS EVO devices were successfully implanted in all subjects to treat a total number of six intracranial aneurysms. No device-related intraprocedural complications were seen. At early clinical follow-up six out of six (100%) patients had a modified Ranking score of 0-1. Early angiographic and cross-sectional radiological follow-up, available in five out of six (83.3%) of the patients confirmed unchanged aneurysmal occlusion rates. A minor, transitory neurological deficit was recorded in one of the six (16.6%) patients. Mortality was 0%.

conclusionsPreliminary experience in this subset of our patients confirms a notably improved technical behaviour of the novel LVIS EVO stent system when compared to its ancestor LVIS Jr. The enhanced visibility of the stent and the refined delivery/retrieval capabilities of the stent further increase the safety margins of the devices profile, especially in cases of tortuous anatomy.

Indexed as

StentsAdultAngiography, Digital SubtractionAnticoagulantsCerebral AngiographyEmbolization, TherapeuticEndovascular ProceduresEquipment DesignFeasibility StudiesFemaleFluoroscopyHumansIntracranial AneurysmMaleMiddle AgedPlatelet Aggregation InhibitorsAnticoagulantsPlatelet Aggregation InhibitorsAneurysmembolisationintraluminal deviceLVIS EVOstent

Identifiers

PMID32692304
PMCPMC7482042

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.