ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2022
Custom total knee arthroplasty facilitates restoration of constitutional coronal alignment.
Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 34 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
34 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- No clinical advantage with customized individually made implants over conventional off-the-shelf implants in total knee arthroplasty: a systematic review and meta-analysis.Archives of orthopaedic and trauma surgery · 2024Pooled it
- No significant difference in early clinical outcomes of custom versus off-the-shelf total knee arthroplasty: a systematic review and meta-analysis.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023Pooled it
- [Expert consensus on clinical pathway for high-conformity total knee arthroplasty through a minimally invasive surgical approach].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2026Article
- Individualised total knee arthroplasty demonstrates 99.4% survival at 3 to 5 years.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026Observational
- Individualized Total Knee Arthroplasty Using the OriginJournal of clinical medicine · 2026Article
- Alignment and/or ligament balancing? Towards truly personalized total knee arthroplasty-A narrative review.Journal of experimental orthopaedics · 2026Review
- Patient-Specific Restoration of Constitutional Alignment Within Predefined Safety Boundaries Using Three-Dimensional Navigation in Primary Total Knee Arthroplasty: One-Year Clinical and Radiographic Outcomes.Journal of clinical medicine · 2026Article
- Differences in characteristic morphological variability among distal femurs based on sex and ethnicity.Bone & joint open · 2026Article
- Review
- [The importance of individual knee arthroplasty].Orthopadie (Heidelberg, Germany) · 2025Article
- Beyond the CPAK dogma: robotic FA preserves CPAK better than MA but with equivalent proms at 5-year follow-up.Archives of orthopaedic and trauma surgery · 2025Article
- A review of patient matched implants for shoulder arthroplasty.JSES international · 2025Review
- How New Technologies Will Transform Total Knee Arthroplasty from a Singular Surgical Procedure to a Holistic Standardized Process.Journal of clinical medicine · 2025Article
- Increased implant thickness in mechanically aligned off-the-shelf total knee replacement compared to bone resection.Journal of experimental orthopaedics · 2025Article
- [New technologies in total knee arthroplasty : Current concepts and personalized treatment strategies].Orthopadie (Heidelberg, Germany) · 2025Review
- Fully automated workflow for designing patient-specific orthopaedic implants: Application to total knee arthroplasty.PloS one · 2025Article
- Custom total knee arthroplasty with personalised alignment showed better 2-year functional outcome compared to off-the-shelf arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2024Article
- Advancements and Strategies in Robotic Planning for Knee Arthroplasty in Patients with Minor Deformities.Life (Basel, Switzerland) · 2024Article
- The Optimal Variation Range of Posterior Condylar Offset Associated with Positive Clinical Outcomes of Primary Total Knee Arthroplasty: A Retrospective Analysis.Orthopaedic surgery · 2024Article
- Assessment of preoperative planning and intraoperative accuracy of the AIKNEE system for total knee arthroplasty.BMC musculoskeletal disorders · 2024Article
Corrections and comments
- Erratum issued
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo describe a strategy for coronal alignment using a computed tomography (CT) based custom total knee arthroplasty (TKA) system, and to evaluate the agreement between the planned and postoperative Hip-Knee-Ankle (HKA) angle, Femoral Mechanical Angle (FMA) and Tibial Mechanical Angle (TMA).
methodsFrom a consecutive series of 918 primary TKAs, 266 (29%) knees received CT-based posterior-stabilized cemented custom TKA. In addition to a preoperative CT-scan, pre- and post-operative radiographs of weight-bearing long leg, anterior-posterior and lateral views of the knee were obtained, on which the FMA, TMA and HKA angles were measured. CT-based three-dimensional (3D) models enabled to correct for cases with bony wear by referring to the non-worn areas and to estimate the native pre-arthritic angles. The alignment technique aimed to preserve or restore constitutional alignment (CA) within predetermined limits, by defining a 'target zone' based on three criteria: 1) a ± 3° (range 87°-93°) primary tolerance for the femoral and tibial resections; 2) a ± 2° secondary tolerance for component obliquity, extending the bounds for FMA and TMA (range 85°-95°); 3) a planned HKA angle range of 175°-183°. Agreement between preoperative, planned and postoperative measurements of FMA, TMA and HKA angle were calculated using intra-class correlation coefficients (ICC).
resultsPreoperative radiograph and CT-scan measurements revealed that, respectively, 73 (28%) and 103 (40%) knees were in the 'target zone', whereas postoperative radiographs revealed that 217 (84%) TKAs were in the 'target zone'. Deviation from the planned angles were - 0.5° ± 1.8° for FMA, - 0.5° ± 1.8° for TMA, and - 1.1° ± 2.1° for HKA angle. Finally, the agreement between the planned and achieved targets, indicated by ICC, were good for FMA (0.701), fair for TMA (0.462) and fair for HKA angle (0.472).
conclusionUsing this strategy for coronal alignment, 84% of custom TKAs were within the 'target zone' for FMA, TMA and HKA angles. These findings support the concepts of emerging personalized medicine technologies, and emphasise the importance of accurate strategies for preoperative planning, which are key to achieving satisfactory 'personalised alignment' that can further be improved by customisation of implant components. LEVEL OF EVIDENCE: IV.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.