Evidence map›Paper›PMID 32679623›Full record

ArticleMedical physics2020

Optimization for customized trajectories in cone beam computed tomography.

Sepideh Hatamikia, Ander Biguri, Gernot Kronreif, Joachim Kettenbach, Tom Russ, Hugo Furtado, Lalith Kumar Shiyam Sundar, Martin Buschmann, Ewald Unger, Michael Figl and 2 more

Abstract read
In one paragraph

Article in Medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Article
  2. Limited-Angle Tomography Using a Neural Network as the Objective Function.International journal of biomedical research & practice · 2025
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Universal orbit design for metal artifact elimination.Physics in medicine and biology · 2022
    Article
  10. Review
  11. Article
  12. Fast CBCT Reconstruction using Convolutional Neural Networks for Arbitrary Robotic C-arm Orbits.Proceedings of SPIE--the International Society for Optical Engineering
    Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Sepideh HatamikiaAustrian Center for Medical Innovation and Technology, Wiener Neustadt, Austria.
Ander BiguriInstitute of Nuclear Medicine, University College London, Bloomsbury, UK.
Gernot KronreifAustrian Center for Medical Innovation and Technology, Wiener Neustadt, Austria.
Joachim KettenbachInstitute of Diagnostic, Interventional Radiology and Nuclear Medicine, Landesklinikum, Wiener Neustadt, Austria.
Tom RussComputer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Heidelberg, Germany.
Hugo FurtadoDepartment of Radiation Oncology, Medical University of Vienna, Vienna, Austria.
Lalith Kumar Shiyam SundarCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Martin BuschmannDepartment of Radiation Oncology, Medical University of Vienna, Vienna, Austria.
Ewald UngerCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Michael FiglCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Dietmar GeorgDepartment of Radiation Oncology, Medical University of Vienna, Vienna, Austria.
Wolfgang BirkfellnerCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.

Funding

ACMIT
6 · The paper itself

Abstract

purposeWe developed a target-based cone beam computed tomography (CBCT) imaging framework for optimizing an unconstrained three dimensional (3D) source-detector trajectory by incorporating prior image information. Our main aim is to enable a CBCT system to provide topical information about the target using a limited angle noncircular scan orbit with a minimal number of projections. Such a customized trajectory should include enough information to sufficiently reconstruct a particular volume of interest (VOI) under kinematic constraints, which may result from the patient size or additional surgical or radiation therapy-related equipment.

methodsA patient-specific model from a prior diagnostic computed tomography (CT) volume is used as a digital phantom for CBCT trajectory simulations. Selection of the best projection views is accomplished through maximizing an objective function fed by the imaging quality provided by different x-ray positions on the digital phantom data. The final optimized trajectory includes a limited angular range and a minimal number of projections which can be applied to a C-arm device capable of general source-detector positioning. The performance of the proposed framework is investigated in experiments involving an in-house-built box phantom including spherical targets as well as an Alderson-Rando head phantom. In order to quantify the image quality of the reconstructed image, we use the average full-width-half-maximum (FWHM

resultsOur experiments based on both the box and head phantom showed that optimized trajectories could achieve a comparable image quality in the VOI with respect to the standard C-arm circular CBCT while using approximately one quarter of projections. We achieved a relative deviation <7% for FWHM

conclusionWe demonstrated that applying limited angle noncircular trajectories with optimized orientations in 3D space can provide a suitable image quality for particular image targets and has a potential for limited angle and low-dose CBCT-based interventions under strong spatial constraints.

Indexed as

AlgorithmsCone-Beam Computed TomographyHumansImage Processing, Computer-AssistedPhantoms, ImagingRadionuclide Imagingcone beam computed tomography (CBCT)image-guided therapy (IGT)limited angle noncircular scan orbitssource-detector trajectory optimizationtomographic reconstruction

Identifiers

PMID32679623
PMCPMC7693244

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.