Evidence map›Paper›PMID 32678824›Full record

ArticlePloS one2020

Long term change of the optic disc and OCT parameters during myopic shift in children with large cup to disc ratio.

Ye Jin Ahn, Yoo Yeon Park, Shin Hae Park, Sun Young Shin

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.0field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Optical coherence tomography characteristics in myopic children with large cup-disc ratios.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026
    Article
  2. Article
  3. Change of ocular parameters in children with large cup-to-disc ratio and interocular cup-to-disc ratio asymmetry.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2021
    Observational
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Ye Jin AhnDepartment of Ophthalmology and Visual Science, Seoul St Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Yoo Yeon ParkDepartment of Ophthalmology and Visual Science, Seoul St Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Shin Hae ParkDepartment of Ophthalmology and Visual Science, Seoul St Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Sun Young ShinDepartment of Ophthalmology and Visual Science, Seoul St Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.ORCID 0000-0001-5978-8611
The Catholic University of Korea Seoul St. Mary's Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis observational case series was to determine long term optic disc changes in eyes with large cup to disc ratio (CDR) and compare the changes induced by myopic shift during childhood with normal control eyes.

methodsChildren under 15 years of age who developed myopia with serial optic disc photographs and spectral domain (SD)-optical coherence tomography (OCT) images with a minimal interval of three years were evaluated. Children with average CDR ≥ 0.6 on SD-OCT were classified as having large CDR. The ratios of vertical disc diameter (VDD), horizontal disc diameter (HDD), and maximum peripapillary atrophy (PPA) width (PPW) were measured to quantify morphologic changes of optic discs and SD-OCT parameters, such as peripapillary retinal nerve fiber layer (RNFL) thickness and macular ganglion cell and inner plexiform layer (GCIPL) thickness were measured.

resultsOf the 82 eyes (82 patients) analyzed, 42 eyes had large CDR and 40 eyes were normal controls. The mean age and refractive error at initial examination were not different between groups (P = 0.33, P = 0.76, respectively). The changes in HDD/VDD and PPW/VDD ratios during follow-up showed no significant difference among the groups (P = 0.45, P = 0.62, respectively). No statistical significance was found in changes in RNFL and GCIPL thickness between the two groups (P = 0.74, P = 0.79, respectively).

conclusionsChildren with enlarged CDR showed changes in optic disc morphology and RNFL/GCIPL thickness similar to normal children during myopic shift.

Indexed as

Tomography, Optical CoherenceCase-Control StudiesChildFemaleHumansMaleMyopiaOptic DiskOrgan SizeTime Factors

Identifiers

PMID32678824
PMCPMC7367476
OpenAlexW3043374958

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.