ArticleOrthopaedic surgery2020
Optimal Sagittal Insertion Depth and Direction of Femoral Intramedullary Rod in Total Knee Arthroplasty in Chinese Osteoarthritis Patients.
Article in Orthopaedic surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 3 citations in OpenAlex.
- Accuracy and reproducibility analysis of different reference axes for femoral prosthesis rotation alignment in TKA based on 3D CT femoral model.BMC musculoskeletal disorders · 2023Article
- Notching is less, if femoral component sagittal positioning is planned perpendicular to distal femur anterior cortex axis, in navigated TKA.Knee surgery & related research · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
Abstract
objectiveTo identify the optimal femoral intramedullary rod insertion depth and direction on the sagittal plane in total knee arthroplasty (TKA) of Chinese osteoarthritis (OA) patients.
methodsFrom January to December 2019, CT data were collected for 85 consecutive entire lower extremity Chinese OA patients. A three-dimensional method was used to simulate intramedullary rod penetration. The intramedullary rods were inserted toward the anterior (TA), center (TC), and posterior (TP) of the femoral canal, respectively. Four penetration depths of 150, 200, 250, and 300 mm from the joint line were set. The intersection angle was measured between the simulated intramedullary rod and the mechanical axis of the femur (FMA) on the sagittal plane.
resultsOur study included 85 Chinese OA patients: 46 women, with a mean age of 65.7 ± 8.4 years (range, 51-85 years) and 39 men, with a mean age of 65.6 ± 8.1 years (range, 46-86 years). The intersection angle between the FMA and the femoral anatomical axis was smaller in men, 2.4° ± 1.6° (range, 0°-4.8°), than in women, 3.5° ± 2.3° (range, 0.7º-8.2°), with a significant statistical difference (P < 0.01). In the comparison of the intersection angle between the simulated intramedullary rod and the FMA, there was no statistical difference between TA200 and TC200 in women (P > 0.05). The proportions were up to 91% and 96% of TA200 at 0°-3° and 0°-5° intervals, respectively, but just 63% and 78% in TC200. In TA150, 76% of intersection angles were greater than 5°. Only approximately 60% in TA250 and TA300 were within the 0°-5° interval and 40% were less than 0°. Only 57% of intersection angles in TC150 were in the 0°-3° interval. TC250, TC300, and TP150 were mostly below 0°. In men, there were statistical differences between all groups. All intersection angles were greater than 5° in TA150. TA200 and TA250 were mostly greater than 5° (87% and 59%, respectively) and 72% of intersection angles were within 0°-5° interval in TA300. TC150 had 92% of intersection angles within the 0°-5° interval but only 62% between the 0° and 3° interval. In the TC200, up to 90% and 97% were within 0°-3° and 0°-5° intervals, respectively. TC300, TP150, and TP200 were mostly below 0°.
conclusionWe described an innovative method for rapidly, simply, and accurately identifying the sagittal insertion depth and direction of the femoral intramedullary rod in TKA, which can optimize the position of the femoral prosthetic component on the sagittal plane in TKA.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.