ArticleMedical physics2020
Sensitivity of IROC phantom performance to radiotherapy treatment planning system beam modeling parameters based on community-driven data.
Article in Medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 1 synthesis or guideline pooled it.
- AAPM MEDICAL PHYSICS PRACTICE GUIDELINE 5.b: Commissioning and QA of treatment planning dose calculations-Megavoltage photon and electron beams.Journal of applied clinical medical physics · 2022Guideline
- Accelerated and standardized commissioning of a robotic RadioSurgery system using a hybrid golden beam data model.Journal of applied clinical medical physics · 2026Article
- Developing reference plans for evaluating global clinical trials credentialing and PSQA systems.Journal of applied clinical medical physics · 2025Article
- Dosimetric sensitivity of an enhanced leaf model (ELM) for individual versus averaged machines.Journal of applied clinical medical physics · 2025Article
- A radiotherapy community data-driven approach to determine which complexity metrics best predict the impact of atypical TPS beam modeling on clinical dose calculation accuracy.Journal of applied clinical medical physics · 2024Article
- Accuracy and reliability of a commercial treatment planning system in nontarget regions in modern prostate radiotherapy.Journal of applied clinical medical physics · 2023Article
- Statistical process control to monitor use of a web-based autoplanning tool.Journal of applied clinical medical physics · 2022Article
- Golden beam data provided by linear accelerator manufacturers should be used in the commissioning of treatment planning systems.Physical and engineering sciences in medicine · 2022Article
- Examination of conversion method of dose distribution of lung cancer IMRT using fluence reversible calculation function in O-ring type linac and C-type linac.Physical and engineering sciences in medicine · 2022Article
- Photon beam modeling variations predict errors in IMRT dosimetry audits.Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2022Article
- Potential dose variability for small-field plans delivered with Elekta Agility collimators.Journal of applied clinical medical physics · 2021Article
- Unlocking a closed system: dosimetric commissioning of a ring gantry linear accelerator in a multivendor environment.Journal of applied clinical medical physics · 2021Article
- Evaluating Mobius3D Dose Calculation Accuracy for Small-Field Flattening- Filter-Free Photon Beams.Technology in cancer research & treatmentArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
purposeTreatment planning system (TPS) dose calculations have previously been shown to be sensitive to modeling errors, especially when treating with complex strategies like intensity-modulated radiation therapy (IMRT). This work investigates the dosimetric impact of several dosimetric and nondosimetric beam modeling parameters, based on their distribution in the radiotherapy community, in two commercial TPSs in order to understand the realistic potential for dose deviations and their clinical effects. METHODS AND MATERIALS: Beam models representing standard 120-leaf Varian Clinac-type machines were developed in Eclipse 13.5 (AAA algorithm) and RayStation 9A (v8.99, collapsed-cone algorithm) based upon median values of dosimetric measurements from Imaging and Radiation Oncology Core (IROC) Houston site visit data and community beam modeling parameter survey data in order to represent a baseline linear accelerator. Five clinically acceptable treatment plans (three IMRT, two VMAT) were developed for the IROC head and neck phantom. Dose distributions for each plan were recalculated after individually modifying parameters of interest (e.g., MLC transmission, percent depth doses [PDDs], and output factors) according to the 2.5th to 97.5
resultsFor Eclipse, dose calculations were sensitive to changes in the dosimetric leaf gap (DLG), which resulted in differences from -5% to +3% to the targets relative to the baseline beam model. Modifying the MLC transmission factor introduced differences up to ± 1%. For RayStation, parameters determining MLC behaviors likewise contributed substantially; the MLC offset introduced changes in dose from -4% to +7%, and the MLC transmission caused changes of -4% to +2%. Among the dosimetric qualities examined, changes in PDD implementation resulted in the most substantial changes, but these were only up to ±1%. Other dosimetric factors had <1% impact on dose accuracy. Interplay between impactful parameters was found to be minimal.
conclusionFactors related to the modeling of the MLC, particularly relating to the leaf offset, can cause clinically significant changes in the calculated dose for IMRT and VMAT plans. This should be of concern to the radiotherapy community because the clinical effects of poor TPS commissioning were based on reported data from clinically implemented beam models. These results further reinforce that dose errors caused by poor TPS calculations are often involved in IROC phantom failures.