Evidence map›Paper›PMID 32676744›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2022

CT-based patient-specific instrumentation for total knee arthroplasty in over 700 cases: single-use instruments are as accurate as standard instruments.

Stefan Gaukel, Raphael N Vuille-Dit-Bille, Michel Schläppi, Peter P Koch

Open access · hybridAbstract read
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
2.2field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it, 15 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Stefan GaukelDepartment of Orthopedics and Traumatology, Cantonal Hospital Winterthur, Brauerstrasse 15, 8409, Winterthur, Switzerland. stefan.gaukel@ksw.ch.ORCID http://orcid.org/0000-0002-8882-4623
Raphael N Vuille-Dit-BilleDepartment of Pediatric Surgery, University Children's Hospital of Basel, Basel, Switzerland.
Michel SchläppiDepartment of Orthopedics and Traumatology, Cantonal Hospital Winterthur, Brauerstrasse 15, 8409, Winterthur, Switzerland.
Peter P KochDepartment of Orthopedics and Traumatology, Cantonal Hospital Winterthur, Brauerstrasse 15, 8409, Winterthur, Switzerland.
Kantonsspital Winterthur · CHUniversity Children’s Hospital Basel · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeEfforts in total knee arthroplasty are made to improve accuracy for a correct leg axis and reduce component malpositioning using patient-specific instruments. It was hypothesized that use of patient-specific instruments (vs. computer-navigated and conventional techniques) will reduce the number of outliers. Our second hypothesis was that single-use instrumentation will lead to the same accuracy compared to patient-specific instruments made of metal.

methods708 primary total knee arthroplasties between 2014 and 2018 using computer tomography (CT)-based patient-specific cutting block technique and a preoperative planning protocol were retrospectively reviewed. Preoperative data [hip-knee-angle (HKA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), tibial slope, femoral component flexion] was compared to postoperative performed standard radiological follow-up X-rays. Differences of > 3° between measurements were defined as outliers.

resultsOverall 500 prostheses using standard instrumentation and 208 prostheses using single-use instruments were implanted. Preoperative HKA axes (- 1.2°; p < 0.001), femoral component flexion (Δ 0.8°, p < 0.001), LDFA (Δ - 1.5°, p < 0.001), MPTA (Δ - 0.5°, p < 0.001) and tibial posterior slopes (Δ 0.5°, p < 0.001), respectively, were different from postoperative axes. More outliers occurred using standard (vs. single-use) instruments (p < 0.001) regarding postoperative HKA (ranges of standard- vs. single-use: instruments: HKA 178.0°-180.5° vs. 178.0°-180.5°, femoral component flexion 0.0°-6.0° vs. 0.0°-4.5°, LDFA 90.0°-91.0° vs. 90.0°-90.0°, MPTA 90.0°-90.0° vs. 90.0°-90.0°, tibial posterior slope - 10° to 10° vs. - 1° to 10°). No differences were seen for other angles measured. Comparing both systems, total number of outliers was higher using standard (8%) vs. single-use instruments (4.3%).

conclusionThis study shows a high accuracy of CT-based patient-specific instrumentation concerning postoperative achieved knee angles and mechanical leg axes. Single-use instruments showed a similar accuracy. LEVEL OF EVIDENCE: III.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisOsteoarthritis, KneeComputersHumansKnee JointRetrospective StudiesTomography, X-Ray ComputedComponent positioningPatient-specific instrumentationPatient-specific instrumentsSingle-use instrumentsTotal knee arthroplasty

Identifiers

PMID32676744
PMCPMC8866287
OpenAlexW3042238345

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.