Prototype system for interventional dual-energy subtraction angiography.

Michael A Speidel, Christiane S Burton, Ethan P Nikolau, Sebastian Schafer, Paul F Laeseke

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Flat-panel dual-energy head computed tomography in the angiography suite after thrombectomy for acute stroke: A clinical feasibility study.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026
    Article
  2. Article
  3. Article
  4. Design Optimization of A Triple-Layer Flat-Panel Detector for Three-Material Decomposition.Proceedings of SPIE--the International Society for Optical Engineering · 2024
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Michael A SpeidelDept. of Medical Physics, Univ. of Wisconsin - Madison, Madison, WI, USA.
Christiane S BurtonDept. of Radiology, Univ. of Wisconsin - Madison, Madison, WI, USA.
Ethan P NikolauDept. of Medical Physics, Univ. of Wisconsin - Madison, Madison, WI, USA.
Sebastian SchaferSiemens Healthineers, Hoffman Estates, IL, USA.
Paul F LaesekeDept. of Radiology, Univ. of Wisconsin - Madison, Madison, WI, USA.

Funding

Dual-Energy Subtraction Angiography for Transcatheter InterventionsR21EB023008 · NIBIB · UNIVERSITY OF WISCONSIN-MADISON · PI SPEIDEL, MICHAEL A · 2017 to 2018
$408k
NIBIB NIH HHS R21 EB023008
6 · The paper itself

Abstract

Dual-energy subtraction angiography (DESA) using fast kV switching has received attention for its potential to reduce misregistration artifacts in thoracic and abdominal imaging where patient motion is difficult to control; however, commercial interventional solutions are not currently available. The purpose of this work was to adapt an x-ray angiography system for 2D and 3D DESA. The platform for the dual-energy prototype was a commercially available x-ray angiography system with a flat panel detector and an 80 kW x-ray tube. Fast kV switching was implemented using custom x-ray tube control software that follows a user-defined switching program during a rotational acquisition. Measurements made with a high temporal resolution kV meter were used to calibrate the relationship between the requested and achieved kV and pulse width. To enable practical 2D and 3D imaging experiments, an automatic exposure control algorithm was developed to estimate patient thickness and select a dual-energy switching technique (kV and ms switching) that delivers a user-specified task CNR at the minimum air kerma to the interventional reference point. An XCAT-based simulation study conducted to evaluate low and high energy image registration for the scenario of 30-60 frame/s pulmonary angiography with respiratory motion found normalized RMSE values ranging from 0.16% to 1.06% in tissue-subtracted DESA images, depending on respiratory phase and frame rate. Initial imaging in a porcine model with a 60 kV, 10 ms, 325 mA / 120 kV, 3.2 ms, 325 mA switching technique demonstrated an ability to form tissue-subtracted images from a single contrast-enhanced acquisition.

Indexed as

C-armdigital subtraction angiographydual-energyinterventional procedures

Identifiers

PMID32669753
PMCPMC7362684

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.