Incubator-based Sound Attenuation: Active Noise Control In A Simulated Clinical Environment.

George Hutchinson, Lilin Du, Kaashif Ahmad

Open access · goldAbstract readEvaluation Study
In one paragraph

Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
4.6field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 20 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

George HutchinsonInvictus Medical, Inc., San Antonio, Texas, United States of America.ORCID 0000-0002-9085-7790
Lilin DuInvictus Medical, Inc., San Antonio, Texas, United States of America.
Kaashif AhmadPediatrix Medical Group, San Antonio, Texas, United States of America.
Invictus Medical (United States) · USBaylor College of Medicine · US

Funding

Incubator-based active noise control system validation in realistic NICU environmentR43DC018464 · NIDCD · INVICTUS MEDICAL, INC. · PI HUTCHINSON, GEORGE · 2019 to 2019
$222k
NIDCD NIH HHS R43 DC018464
6 · The paper itself

Abstract

objectiveNoise in the neonatal intensive care unit can be detrimental to the health of the hospitalized infant. Means of reducing that noise include staff training, warning lights, and ear coverings, all of which have had limited success. Single family rooms, while an improvement, also expose the hospitalized infant to the same device alarms and mechanical noises found in open bay units.

methodsWe evaluated a non-contact incubator-based active noise control device (Neoasis™, Invictus Medical, San Antonio, Texas) in a simulated neonatal intensive care unit (NICU) setting to determine whether it could effectively reduce the noise exposure of infants within an incubator. In the NICU simulation center, we generated a series of clinically appropriate sound sequences with bedside medical devices such as a patient monitor and fluid infusion devices, hospital air handling systems, and device mechanical sounds. A microphone-equipped infant mannequin was oriented within an incubator. Measurements were made with the microphones with the Neoasis™ deactivated and activated.

resultsThe active noise control device decreased sound pressure levels for certain alarm sounds by as much as 14.4 dB (a 5.2-fold reduction in sound pressure) at the alarm tone's primary frequency. Frequencies below the 2 kHz octave band were more effectively attenuated than frequencies at or above the 2 kHz octave band. Background noise levels below 40 dBA were essentially not impacted by the active noise control device.

conclusionsThe active noise control device further reduces noise inside infant incubators. Device safety and potential health benefits of the quieter environment should be verified in a clinical setting.

Indexed as

Incubators, InfantIntensive Care Units, NeonatalChild DevelopmentEquipment SafetyHumansInfant HealthInfant, NewbornInfant, PrematureManikinsNoiseTexas

Identifiers

PMID32667931
PMCPMC7363066
OpenAlexW3042282956

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.