Evidence map›Paper›PMID 32667452›Full record

ArticleRevista Brasileira de terapia intensiva2020

Frequency and characterization of the use of cuffed tracheal tubes in neonatal and pediatric intensive care units in Brazil.

João Paulo Berti Buzzi Rodrigues, Suzi Laine Longo Dos Santos Bacci, Janser Moura Pereira, Cíntia Johnston, Vivian Mara Gonçalves de Oliveira Azevedo

Open access · diamondAbstract read
In one paragraph

Article in Revista Brasileira de terapia intensiva, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.3field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Use of noninvasive mechanical ventilation weaning protocol in neonatal intensive care units in Brazil: a descriptive study.Revista paulista de pediatria : orgao oficial da Sociedade de Pediatria de Sao Paulo · 2023
    Article
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

João Paulo Berti Buzzi RodriguesPrograma de Residência em Área Profissional da Saúde (Uni e Multiprofissional), Faculdade de Medicina, Universidade Federal de Uberlândia, Uberlândia, MG, Brasil.
Suzi Laine Longo Dos Santos BacciPrograma de Residência em Área Profissional da Saúde (Uni e Multiprofissional), Faculdade de Medicina, Universidade Federal de Uberlândia, Uberlândia, MG, Brasil.
Janser Moura PereiraFaculdade de Matemática, Universidade Federal de Uberlândia, Uberlândia, MG, Brasil.
Cíntia JohnstonDepartamento de Pediatria, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brasil.
Vivian Mara Gonçalves de Oliveira AzevedoFaculdade de Educação Física e Fisioterapia, Universidade Federal de Uberlândia, Uberlândia, MG, Brasil.
Associação Saúde da Família · BRUniversidade de São Paulo · BRUniversidade Federal de Uberlândia · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo identify the neonatal, pediatric and mixed (neonatal and pediatric) intensive care units in Brazil that use cuffed tracheal tubes in clinical practice and to describe the characteristics related to the use of protocols and monitoring.

methodsTo identify the intensive care units in Brazil, the Ministry of Health's National Registry of Health Facilities was accessed, and information was collected on 693 registered intensive care units. This was an analytical cross-sectional survey conducted through electronic questionnaires sent to 298 neonatal, pediatric and mixed intensive care units in Brazil.

resultsThis study analyzed 146 questionnaires (49.3% from neonatal intensive care units, 35.6% from pediatric intensive care units and 15.1% from mixed pediatric intensive care units). Most of the participating units (78/146) used cuffed tracheal tubes, with a predominance of use in pediatric intensive care units (52/78). Most of the units that used cuffed tracheal tubes applied a cuff pressure monitoring protocol (45/78). The use of cuff monitoring protocols was observed in intensive care units with a physical therapy service exclusive to the unit (38/61) and in those with a physical therapist present 24 hours/day (25/45). The most frequent cause of extubation failure related to the use of cuffed tracheal tubes in pediatric intensive care units was upper airway obstruction.

conclusionIn this survey, the use of cuffed tracheal tubes and the application of a cuff pressure monitoring protocol was predominant in pediatric intensive care units. The use of a monitoring protocol was more common in intensive care units that had a physical therapist who was exclusive to the unit and was present 24 hours/day.

Indexed as

Intensive Care Units, NeonatalIntensive Care Units, PediatricAdolescentAirway ExtubationBrazilChildChild, PreschoolCross-Sectional StudiesEquipment DesignHumansInfantInfant, NewbornIntubation, IntratrachealPhysical TherapistsSurveys and QuestionnairesYoung Adult

Identifiers

PMID32667452
PMCPMC7405737
OpenAlexW3041468155

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.