Evidence map›Paper›PMID 32666182›Full record

ArticleJapanese journal of radiology2020

Feasibility of computed tomography texture analysis of hepatic fibrosis using dual-energy spectral detector computed tomography.

ByukGyung Choi, In Young Choi, Sang Hoon Cha, Suk Keu Yeom, Hwan Hoon Chung, Seung Hwa Lee, Jaehyung Cha, Ju-Han Lee

Abstract read
PubMed Publisher
In one paragraph

Article in Japanese journal of radiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Trial
  2. Review
  3. Article
  4. Dual-energy CT: minimal essentials for radiologists.Japanese journal of radiology · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

ByukGyung ChoiDepartment of Radiology, Korea University College of Medicine, 123 Jeokgeum-ro, Danwon-gu, Ansan, 15355, Republic of Korea.
In Young ChoiDepartment of Radiology, Korea University College of Medicine, 123 Jeokgeum-ro, Danwon-gu, Ansan, 15355, Republic of Korea. ciy1114@naver.com.ORCID http://orcid.org/0000-0001-5264-675X
Sang Hoon ChaDepartment of Radiology, Korea University College of Medicine, 123 Jeokgeum-ro, Danwon-gu, Ansan, 15355, Republic of Korea.
Suk Keu YeomDepartment of Radiology, Korea University College of Medicine, 123 Jeokgeum-ro, Danwon-gu, Ansan, 15355, Republic of Korea.
Hwan Hoon ChungDepartment of Radiology, Korea University College of Medicine, 123 Jeokgeum-ro, Danwon-gu, Ansan, 15355, Republic of Korea.
Seung Hwa LeeDepartment of Radiology, Korea University College of Medicine, 123 Jeokgeum-ro, Danwon-gu, Ansan, 15355, Republic of Korea.
Jaehyung ChaDepartment of Biostatistics, Korea University College of Medicine, 123 Jeokgeum-ro, Danwon-gu, Ansan, 15355, Republic of Korea.
Ju-Han LeeDepartment of Pathology, Korea University Ansan Hospital, Korea University College of Medicine, 123 Jeokgeum-ro, Danwon-gu, Ansan, 15355, Republic of Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate feasibility of computer tomography texture analysis (CTTA) at different energy level using dual-energy spectral detector CT for liver fibrosis. MATERIALS AND

methodsEighty-seven patients who underwent a spectral CT examination and had a reference standard of liver fibrosis (histopathologic findings, n = 61, or clinical findings for normal, n = 26) were included. Mean gray-level intensity, mean number of positive pixels (MPP), entropy, skewness, and kurtosis using commercially available software (TexRAD) were compared at different energy levels. Optimal CTTA parameter cutoffs to diagnose liver fibrosis were evaluated. CTTA parameters at different energy levels correlated with liver fibrosis. The association of CTTA parameters with energy level was evaluated.

resultsMean gray-level intensity, skewness, kurtosis, and entropy showed significant differences between patients with and without clinically significant hepatic fibrosis (P < 0.05). Mean gray-level intensity at 50 keV was significantly positively correlated with liver fibrosis (ρ = 0.502, P < 0.001). To diagnose stages F2-F4, entropy and mean gray-level intensity at low keV level showed the largest area under the curve (AUC; 0.79 and 0.79). Estimated marginal means (EMMs) of mean gray-level intensity showed prominent differences at low energy levels.

conclusionCTTA parameters from different keV levels demonstrated meaningful accuracy for diagnosis of liver fibrosis or clinically significant hepatic fibrosis.

Indexed as

Radiography, Dual-Energy Scanned ProjectionAdultAgedAged, 80 and overFeasibility StudiesFemaleHumansLiverLiver CirrhosisMaleMiddle AgedRetrospective StudiesTomography, X-Ray ComputedDual-energy spectral CTFibrosisLiverQuantitative imagingTexture analysis

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.