ArticleSpinal cord2021
Evaluation of a re-engineered device for penile vibratory stimulation in men with spinal cord injury.
Article in Spinal cord, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 8 citations in OpenAlex.
- Sexuality, Intimacy, and Reproductive Health after Spinal Cord Injury.Journal of personalized medicine · 2022Review
- Penile Vibratory Stimulation for Semen Retrieval in Men with Spinal Cord Injury: Patient Perspectives.Research and reports in urology · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 6 institutions in 4 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
STUDY
designCohort study
objectivesThe purpose of this study was to evaluate the performance of a re-engineered device (Ferticare 2.0), which is replacing the previous standard (Ferticare 1.0) for penile vibratory stimulation in men with spinal cord injury. Most men with spinal cord injury are anejaculatory, requiring medical assistance to obtain their semen. Penile vibratory stimulation is generally recognized as the standard of care for semen retrieval in these anejaculatory men.
settingMajor Research University in Miami, Florida, USA.
methodsThe Ferticare 2.0 device was applied to 15 men with spinal cord injury in a three-step protocol simulating normal use. Step 1: one device (2.5 mm amplitude, 100 Hz) was applied to the glans penis for 2 min. Step 2: If no ejaculation occurred, the amplitude was increased to 4.0 mm (100 Hz) and the device similarly applied. Step 3: If no ejaculation occurred, two devices, each 2.5 mm and 100 Hz were applied to the dorsum and frenulum of the glans penis. Participants at risk for autonomic dysreflexia were pretreated with sublingual nifedipine (20 mg), 15 min prior to stimulation. Blood pressure and other symptoms of autonomic dysreflexia were monitored. Participants answered a questionnaire about their experience with the device.
resultsThirteen of 15 participants ejaculated with the device. No adverse events occurred. All participants commented they would recommend the device to other men with spinal cord injury.
conclusionsA re-engineered device, the Ferticare 2.0, is safe and effective for inducing ejaculation in men with spinal cord injury.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials