Evidence map›Paper›PMID 32661713›Full record

ArticleSurgical endoscopy2021

Short-term outcome of routine use of EndoFLIP during hiatal hernia repair.

Ugoeze Nwokedi, Duc T Nguyen, Leonora M Meisenbach, Ray Chihara, Edward Y Chan, Edward A Graviss, Min P Kim

Abstract read
PubMed Publisher
In one paragraph

Article in Surgical endoscopy, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
1.8field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 20 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Ugoeze NwokediDivision of Thoracic Surgery, Department of Surgery, Houston Methodist Hospital, 6550 Fannin Street, Suite 1661, Houston, TX, 77030, USA.
Duc T NguyenDepartment of Pathology and Genomic Medicine, Houston Methodist Research Institute, Houston, TX, USA.ORCID http://orcid.org/0000-0002-5059-4404
Leonora M MeisenbachDivision of Thoracic Surgery, Department of Surgery, Houston Methodist Hospital, 6550 Fannin Street, Suite 1661, Houston, TX, 77030, USA.
Ray ChiharaDivision of Thoracic Surgery, Department of Surgery, Houston Methodist Hospital, 6550 Fannin Street, Suite 1661, Houston, TX, 77030, USA.
Edward Y ChanDivision of Thoracic Surgery, Department of Surgery, Houston Methodist Hospital, 6550 Fannin Street, Suite 1661, Houston, TX, 77030, USA.
Edward A GravissDepartment of Pathology and Genomic Medicine, Houston Methodist Research Institute, Houston, TX, USA.ORCID http://orcid.org/0000-0003-1024-5813
Min P KimDivision of Thoracic Surgery, Department of Surgery, Houston Methodist Hospital, 6550 Fannin Street, Suite 1661, Houston, TX, 77030, USA. mpkim@houstonmethodist.org.ORCID http://orcid.org/0000-0003-0941-8609
Houston Methodist · USCornell University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundEndoluminal functional lumen imaging probe (EndoFLIP) technology is a tool that can be used to provide intraoperative objective real-time feedback during hiatal hernia repair. We wanted to determine the implication of initial distensibility index (DI) after mobilization of hiatus and final DI after creation of barrier in short-term clinical outcomes.

methodsWe performed a retrospective analysis of prospectively collected data on the intraoperative use of EndoFLIP during hiatal hernia repair at a single institution from 2017 to 2019. We analyzed the initial DI and final DI with the short-term clinical outcomes.

resultsThere were 163 patients who had Nissen (n = 16), Toupet (n = 79) or magnetic sphincter augmentation (n = 68) with (n = 158) or without (n = 5) hiatal hernia repair with median initial DI was 3.2 mm

conclusionsThe initial DI was associated with final DI, but it did not correlate with improvement in short-term GERD-HRQL score. Final DI maintained above the cutoff value led to most of the patients not to require intervention for dysphagia. Use of the EndoFLIP can provide objective data during the operation and prevent severe dysphagia after repair.

Indexed as

Gastroesophageal RefluxHernia, HiatalLaparoscopyFundoplicationHerniorrhaphyHumansRetrospective StudiesTreatment OutcomeDistensibility indexDysphagiaEndoFLIPEndoluminal functional lumen imaging probeGERD-HRQLHiatal hernia repairMagnetic sphincter augmentation

Identifiers

PMID32661713
OpenAlexW3042270558

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.