Evidence map›Paper›PMID 32660019›Full record

ArticleMicromachines2020

Quantitative Image-Based Cell Viability (QuantICV) Assay for Microfluidic 3D Tissue Culture Applications.

Louis Jun Ye Ong, Liang Zhu, Gabriel Jenn Sern Tan, Yi-Chin Toh

Open access · goldAbstract read
In one paragraph

Article in Micromachines, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
0.7field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Article
  6. Article
  7. Review
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Louis Jun Ye OngDepartment of Biomedical Engineering, National University of Singapore, 4, Engineering Drive 3, E4-04-10, Singapore 117583, Singapore.ORCID 0000-0003-2398-7672
Liang ZhuDepartment of Biomedical Engineering, National University of Singapore, 4, Engineering Drive 3, E4-04-10, Singapore 117583, Singapore.ORCID 0000-0002-4305-7539
Gabriel Jenn Sern TanDepartment of Biomedical Engineering, National University of Singapore, 4, Engineering Drive 3, E4-04-10, Singapore 117583, Singapore.
Yi-Chin TohDepartment of Biomedical Engineering, National University of Singapore, 4, Engineering Drive 3, E4-04-10, Singapore 117583, Singapore.
National University of Singapore · SGQueensland University of Technology · AU

Funding

Biomedical Institute for Global Health Research and Technology R-722-000-013-592Ministry of Education - Singapore R-397-000-215-112, R-397-000-253-112, R-397-000-298-114Singapore-MIT Alliance for Research and Technology (SMART) R-722-000-013-592The N.1 Institute for Health R-719-000-100-305
6 · The paper itself

Abstract

Microfluidic 3D tissue culture systems are attractive for in vitro drug testing applications due to the ability of these platforms to generate 3D tissue models and perform drug testing at a very small scale. However, the minute cell number and liquid volume impose significant technical challenges to perform quantitative cell viability measurements using conventional colorimetric or fluorometric assays, such as MTS or Alamar Blue. Similarly, live-dead staining approaches often utilize metabolic dyes that typically label the cytoplasm of live cells, which makes it difficult to segment and count individual cells in compact 3D tissue cultures. In this paper, we present a quantitative image-based cell viability (QuantICV) assay technique that circumvents current challenges of performing the quantitative cell viability assay in microfluidic 3D tissue cultures. A pair of cell-impermeant nuclear dyes (EthD-1 and DAPI) were used to sequentially label the nuclei of necrotic and total cell populations, respectively. Confocal microscopy and image processing algorithms were employed to visualize and quantify the cell nuclei in the 3D tissue volume. The QuantICV assay was validated and showed good concordance with the conventional bulk MTS assay in static 2D and 3D tumor cell cultures. Finally, the QuantICV assay was employed as an on-chip readout to determine the differential dose responses of parental and metastatic 3D oral squamous cell carcinoma (OSCC) to Gefitinib in a microfluidic 3D culture device. This proposed technique can be useful in microfluidic cell cultures as well as in a situation where conventional cell viability assays are not available.

Indexed as

3D cell culturecell viabilitymicrofluidicquantitativetissue culture

Identifiers

PMID32660019
PMCPMC7407956
OpenAlexW3041101042

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.