ArticleJournal of applied clinical medical physics2020

Increasing iterative reconstruction strength at low tube voltage in coronary CT angiography protocols using 3D-printed and Catphan

Kamarul A Abdullah, Mark F McEntee, Warren M Reed, Peter L Kench

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Kamarul A AbdullahFaculty of Health Sciences, Universiti Sultan Zainal Abidin (UniSZA), Kuala Terengganu, Malaysia.ORCID https://orcid.org/0000-0002-3568-9579
Mark F McEnteeMedical Imaging Optimisation and Perception Group (MIOPeG), Discipline of Medical Imaging Science, Faculty of Medicine and Health, Sydney School of Health Sciences, The University of Sydney, Camperdown, NSW, Australia.ORCID https://orcid.org/0000-0001-7045-2190
Warren M ReedMedical Imaging Optimisation and Perception Group (MIOPeG), Discipline of Medical Imaging Science, Faculty of Medicine and Health, Sydney School of Health Sciences, The University of Sydney, Camperdown, NSW, Australia.ORCID https://orcid.org/0000-0002-8937-2198
Peter L KenchMedical Imaging Optimisation and Perception Group (MIOPeG), Discipline of Medical Imaging Science, Faculty of Medicine and Health, Sydney School of Health Sciences, The University of Sydney, Camperdown, NSW, Australia.ORCID https://orcid.org/0000-0002-4327-0321

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe purpose of this study was to investigate the effect of increasing iterative reconstruction (IR) algorithm strength at different tube voltages in coronary computed tomography angiography (CCTA) protocols using a three-dimensional (3D)-printed and Catphan

methodsA 3D-printed cardiac insert and Catphan 500 phantoms were scanned using CCTA protocols at 120 and 100 kVp tube voltages. All CT acquisitions were reconstructed using filtered back projection (FBP) and Adaptive Statistical Iterative Reconstruction (ASIR) algorithm at 40% and 60% strengths. Image quality characteristics such as image noise, signal-noise ratio (SNR), contrast-noise ratio (CNR), high spatial resolution, and low contrast resolution were analyzed.

resultsThere was no significant difference (P > 0.05) between 120 and 100 kVp measures for image noise for FBP vs ASIR 60% (16.6 ± 3.8 vs 16.7 ± 4.8), SNR of ASIR 40% vs ASIR 60% (27.3 ± 5.4 vs 26.4 ± 4.8), and CNR of FBP vs ASIR 40% (31.3 ± 3.9 vs 30.1 ± 4.3), respectively. Based on the Modulation Transfer Function (MTF) analysis, there was a minimal change of image quality for each tube voltage but increases when higher strengths of ASIR were used. The best measure of low contrast detectability was observed at ASIR 60% at 120 kVp.

conclusionsChanging the IR strength has yielded different image quality noise characteristics. In this study, the use of 100 kVp and ASIR 60% yielded comparable image quality noise characteristics to the standard CCTA protocols using 120 kVp of ASIR 40%. A combination of 3D-printed and Catphan

Indexed as

Computed Tomography AngiographyTomography, X-Ray ComputedAlgorithmsCoronary AngiographyHumansPhantoms, ImagingPrinting, Three-DimensionalRadiation DosageRadiographic Image Interpretation, Computer-AssistedSignal-To-Noise Ratio3D printingCTimage qualityiterative reconstructionphantomradiation dose

Identifiers

PMID32657493
PMCPMC7497920

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.