ArticleLasers in medical science2021

Development of a real-time blood damage monitoring device for cardiopulmonary bypass system using near-infrared spectroscopy.

Xuelian Gu, Taotao Wang, Kang Zheng, Ziang Jiang, Hongyan Jiang

Abstract read
PubMed Publisher
In one paragraph

Article in Lasers in medical science, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Xuelian Gu *School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai, 200093, People's Republic of China. guxuelian@usst.edu.cn.
Taotao Wang *School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai, 200093, People's Republic of China.
Kang ZhengSchool of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai, 200093, People's Republic of China.
Ziang JiangSchool of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai, 200093, People's Republic of China.
Hongyan JiangResearch & Engineering Academy MPSC, 1601 Zhangdong Road, Shanghai, 201203, People's Republic of China.

Funding

National Natural Science Foundation of China 11502146
6 · The paper itself

Abstract

The optical properties of hemoglobin could indicate the degree of hemolysis. We aimed to utilize this to develop a real-time blood damage monitoring device for cardiopulmonary bypass (CPB) systems. The real-time blood damage monitoring device comprised a near-infrared spectroscopy optical module with a fiber spectrometer and monitoring platform and computer software developed using LabVIEW 2017. The fiber spectrometer operated at wavelengths of 545, 660, and 940 nm and contained a detector fiber bundle (source-detector distance = 1.0-2.5 cm). CPB operation was simulated using an artificial heart-lung machine with a flow rate of 3, 4, or 5 L/min. Four hundred milliliter of anticoagulated porcine blood was continuously rotated for 4 h. The transmittance, reflectivity, and absorbance of the blood were measured using the optical device at a frequency of 25 Hz and then digitally averaged into 1-s interval. Samples of damaged blood were collected at regular intervals for in vitro hemolysis tests to calculate the normalized index of hemolysis (NIH). All experiments were repeated three times. We prepared 28 blood bags containing 400 ml of anticoagulant. Paired t test was used to examine the test-retest reliability of the differences between the three methods and control samples. Statistical tests revealed significant differences in the mean values between the test and control groups over time (P < 0.01). Relationship was established between the real-time monitoring results and the NIH values. An effective blood damage detection method that combined in vitro hemolysis tests and near-infrared spectroscopy was achieved. The results demonstrate the clinical potential of a real-time, low-cost, and reliable blood damage monitoring device to improve the safety of CPB operation.

Indexed as

Spectroscopy, Near-InfraredCardiopulmonary BypassHeart-Lung MachineHemoglobinsHemolysisHumansReproducibility of ResultsHemoglobinsCardiopulmonary bypassHemolysisNormalized index of hemolysisPhotoelectric monitoring deviceThrombosis