ArticleInternational journal of computer assisted radiology and surgery2020
Accuracy and reliability of computer-assisted semi-automated morphological analysis of intracranial aneurysms: an experimental study with digital phantoms and clinical aneurysm cases.
Article in International journal of computer assisted radiology and surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 21 citations in OpenAlex.
- Insights into the Mechanisms Underlying the Lower Rupture Risk of Paraclinoid Aneurysms: a Comparative Analysis with Other Aneurysm Locations.Clinical neuroradiology · 2026Article
- Commercial AI platforms improve reproducibility but fail to meet clinical precision thresholds for intracranial aneurysm measurement: implications for serial surveillance.BMC medical imaging · 2026Article
- Article
- Discriminators of Paraclinoid Aneurysm Rupture Based On Morphological Computer-Assisted Semiautomated Measurement (CASAM) and Hemodynamic Analysis.Clinical neuroradiology · 2025Article
- Integrated Deep Learning Model for the Detection, Segmentation, and Morphologic Analysis of Intracranial Aneurysms Using CT Angiography.Radiology. Artificial intelligence · 2025Article
- Risk factors of unruptured intracranial aneurysms instability in the elderly.Acta neurochirurgica · 2024Article
- Clinical, 3D Morphological, and Hemodynamic Risk Factors for Instability of Unruptured Intracranial Aneurysms.Clinical neuroradiology · 2023Article
- Development and validation of a deep learning model for prediction of intracranial aneurysm rupture risk based on multi-omics factor.European radiology · 2023Article
- Case Report: Dynamic Changes in Hemodynamics During the Formation and Progression of Intracranial Aneurysms.Frontiers in cardiovascular medicine · 2021Article
- Risk Factors for Pericallosal Artery Aneurysm Rupture Based on Morphological Computer-Assisted Semiautomated Measurement and Hemodynamic Analysis.Frontiers in neuroscience · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 5 institutions in 2 countries.
Funding
Abstract
purposeMorphological parameters are very important for predicting aneurysm rupture. However, due to geometric radiographic distortion and plane/angle selection bias, the traditional manual measurements (MM) of aneurysm morphology are inaccurate and suffer from severe variability. Our study is to evaluate the accuracy and reliability of computer-assisted semi-automated measurement (CASAM) of intracranial aneurysms, which is a novel technique in aneurysm measurement.
methodsAn in-house software for CASAM was developed. Classical morphology indices including aneurysm diameter, neck size, height, width, volume, inflow angle, and aspect ratio were measured. To validate the accuracy and robustness of the semi-automated measurements, 20 digital intracranial aneurysm phantoms and 27 clinical aneurysms with different locations and sizes were measured using MM or CASAM.
resultsIn the phantom study, although the inter-observer variability of both the MM and CASAM was very low, the manual measurements had higher errors (1.7-19.1%), while the CASAM yielded more accurate results (errors of 1.1-2.5%). The consistency test indicated that the CASAM results were highly consistent with the actual values (concordance correlation coefficient = 0.993). In the clinical study, CASAM showed better intraclass correlation coefficient values compared with MM. The inflow angle had low consistency in both groups.
conclusionsWe successfully developed a computer-assisted method to semi-automatically measure the morphological parameters of aneurysm. According to our study, CASAM of aneurysm morphological parameters is a more precise and reliable way than MM to obtain accurate aneurysm morphological parameters. This method is worthy of further studies to promote its clinical use.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials